Installation & Calibration Manual

 

ED2E-Elite SkidWeigh & DL2-E DURA-LIFT  Systems                

             

                 

Lift Truck Onboard Weighing Scale  

                                                                                    

ED2E-Elite  V2200HIAB 

 

Integrated Visual Data Technology Inc.,   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7

    

Summary of Contents for DL2-E Dura-Lift

Page 1: ...n Calibration Manual ED2E Elite SkidWeigh DL2 E DURA LIFT Systems Lift Truck Onboard Weighing Scale ED2E Elite V2200HIAB Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 ...

Page 2: ...ormed by an acknowledged lift truck dealer technician or end user electro and hydraulic technical installer Here are two acceptable methods of making a wire connections Soldering your connections recommended Crimp connectors with the use of the proper crimping tool Regardless of the method you choose ensure that the connection is mechanically sound and properly insulated Use high quality electrica...

Page 3: ...lation of the pressure transducer the hydraulic lift circuit must be pressure free There are two ways to do that 1 Place the forks on the ground in their lowest position and make the hydraulic system pressure free by tilting the mast forward The chain s should be slack 2 Lift the forks and position them on the top of a supporting fixture Start lowering the lifting cylinder into its lowest position...

Page 4: ...osition Brown Wire Battery negative Red Wire connect to RED wire of the pressure transducer cable Black Wire connect to BLACK wire of the pressure transducer cable White Wire connect to WHITE wire of the pressure transducer cable Pressure transducer cable Pressure transducer cable must be connected to the digital indicator seven wires single cable White Wire signal wire 0 to 2 5 V Black Wire negat...

Page 5: ...pped with hydraulic accumulator If the standard ED2E SkidWeigh system is installed on the lift trucks equipped with hydraulic accumulators please contact us to provide you with different digital indicator having specific software algorithm to obtain load weight accuracy within 1 0 of vehicle maximum lifting capacity Weighing function calibration procedure The ED2 Elite SkidWeigh calibration is aut...

Page 6: ...de display digit will change from number 8 to 0 System is ready for automatic zeroing of the scale function When LED display is showing 0 in Mode digit lift the empty forks or attachment such as clamp etc just above the ground After few seconds LED display will show 1 in Mode digit and 0 value in furthest right digit display Automatic zeroing is done Integrated Visual Data Technology Inc 3439 Whil...

Page 7: ...rap around Start with least significant digit In our case this is 0 Use M button to increment to the next digit on LED display To enter the second digit press the M button and Mode digit will increment to the second Keep pressing M button and enter a third forth and fifth values As the input for known load value has only four digits 4000 in our example the fifth digits must be 0 Mode Digit 5 Digit...

Page 8: ... load weight just above the ground LED display will go blank and within few seconds LED display will show the value of calibrated Known load weight of 4000 When you lower the load to the ground system will go automatically into operational mode Mode digit will display number 8 Weighing calibration function is completed and system is ready to be used Integrated Visual Data Technology Inc 3439 Whila...

Page 9: ...rload warning value In our example we will enter the overload value of 4500 Make sure that 0 is inputed for digit number 5 As soon the last digit is inputed into the system Mode 7 will change to Mode 8 which is the normal operational mode Example If the lifted load is above preset overload value of 4500 in our case showing 5489 pounds the LCD display will Show actual overload value LED display wil...

Page 10: ...and hold Arrow Up button Turn ignition switch on to apply power to the system Indicator will show number 8 on all six digit Do not need to hold Arrow Up button Wait for few seconds and Bluetooth Blue LED Light will come on The mobile Bluetooth printer is paired with the system Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 Bluetooth LED Power On LED Lo...

Page 11: ...representing second independent weighing channel Mode 8 is the first weighing channel By pressing two weighing channels switch indication on LED display will change to Mode 82 Note The calibration procedure is the same for the second weighing channel indicated on LED display as Mode 82 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 Two Independent Weig...

Page 12: ...ighing process During the measurement cycle LED light Busy will turn yellow After few seconds LED display will indicated load weight ACCUMULATIVE LOAD WEIGHT TOTAL Optional Use Black Button to accumulate load weigh Use Red Button to reset accumulative load weight total and print ticket if onboard Bluetooth printer is connected to the system OVERLOAD WARNING Optional If the load lifted is above pre...