background image

IDS 805 Quick User Manual 700-266-07A Issued January 2015 

IDS805 Alarm Panel Quick Start Guide

 

THANK YOU FOR CHOOSING IDS TO PROTECT YOU 

Congratulations on your purchase of an IDS805 alarm panel. IDS 
alarm panels are powerful, versatile and highly configurable 
security systems, which should be installed by a professionally 
trained installer.  
This Quick Start Guide covers basic user functionality to get you 
familiar and using the system as quickly as possible. The majority of 
panel features are programmable only by an IDS-accredited 
installer in possession of the INSTALLER CODE, and are identified 
with this symbol

@

.  

Advanced User Functions, are covered in the Advanced User 
Manual, available at 

www.idsprotect.com

UNDERSTANDING ALARM PANEL FUNCTIONS 

When powered up, the panel is either ARMED or DISARMED. 
If DISARMED, it is READY or NOT READY. 
Entering data confirm by Pressing [*]  
[#] to exit programming / menu or to clear data 
Successful data entry – single extendedkeypad beep 
Failed entry – triple keypad beep 

EMERGENCY ALARMS 

Emergency alarms can be triggered: 

-

 

on the keypad by holding down [F] for fire, [P] for panic, or 
[M] for medical keys 

-

 

Via Fixed Panic Buttons installed by the alarm installer, or 

-

 

Via an IDS remote transmitter, holding down any button for 3 
seconds or a dedicated button. (Please confirm with installer) 

ARMINGand DISARMING YOUR ALARM 

The IDS805 panel provides multiple arming methods and modes to 
suit your lifestyle.  

AWAY ARM 

Use AWAY ARM when you are leaving the premises and want all 
entry / exit zones to function as such. 
To away arm: 
1.

 

Enter USER CODE or hold down [1] until keypad beeps 

2.

 

Exit premises before exit delay beep sequence completes 

 

STAY ARM 

Use STAY ARM when you are in the premises and want some zones 

armed and others not 
1.

 

Select your stay profile, if there are more than one and the last 
profile selected is not the profile you want to stay arm in.  
Press [MODE] then [9] [PROFILE NUMBER] [*] 

2.

 

Hold the [5] key until the beep.  

STAY & GO ARM 

Use STAY AND GO when some people are leaving the premises, 
others are remaining at home. Will arm in the last stay profile 
selected if not changed. 
1.

 

Hold [6] until BEEP 

2.

 

Exit premises before exit delay beep sequence completes 

DISARM 

1.

 

Enter through nominated entry zones 

2.

 

Enter USER CODE before count down is complete 

REMOTE ARM / DISARM 

Use your remote transmitter to arm / disarm by pressing the 
programmed button 

WORKING WITH ZONES 

BYPASS A ZONE 

Bypass a zone to prevent it triggering an alarm when armed 
1.

 

Confirm panel is DISARMED 

2.

 

Press [*][ZONE NO], [*][ZONE NO]…[#] 

CHIME ZONES 

The keypad will chime when a CHIME ZONE is violated while the 
panel is DISARMED 
1.

 

Hold [2] until BEEP, [ZONE NO] [*]….[#] 

VIEWING PANEL INFORMATION 

VIEW ALARM MEMORY 

View zones that were violated, bypassed or tampered during the 
last arm cycle 
1.

 

If ARM LED is flashing before disarming, there are events in 
ALARM MEMORY 

2.

 

Confirm panel is DISARMED 

3.

 

Hold [0] till beep 

4.

 

Press [1] [*] to view bypassed zones 

5.

 

Press [2] [*] to view tampered zones 

Note: ALARM MEMORY is cleared with next ARM cycle 

WORKING WITH STAY PROFILES 

STAY PROFILES enable a user to ARM while bypassing programmed 
zones. This is useful when users are in the premises, but want 
some zones armed. 

CREATE STAY ZONES 

STAY ZONES are automatically bypassed when a panel is STAY 
ARMED. STAY ZONES are allocated to one of two STAY PROFILES.  
1.

 

Select the desired STAY PROFILE. Press [MODE] then [9] 
[PROFILE NUMBER] [*] 

2.

 

Allocate STAY ZONE. Hold [3] until BEEP, ZONE NO… [#] 

CREATE BUZZ ZONES 

BUZZ zones give USERS warning of a zone being violation before 
reporting an ALARM to the control room. The keypad will BEEP for 
30 seconds if a BUZZ zone is violated while the panel is STAY 
ARMED. If a valid USER CODE is not entered in this period, an alarm 
status will be reported to the control room. 
1.

 

Hold [4] until BEEP, ZONE NO [*]…[#] 

Note: A zone cannot be a buzz zone and a stay zone 

CODES 

OVERVIEW OF CODES 

The IDS805 Panel supports multiple types of CODES, allowing for 
flexibility in use: 
There are four different types of USER CODES: 

MASTER CODE

, code 1, enables its owner to program certain user 

functions 

USER CODES

, codes 2 to 13, allow users to ARM / DISARM and 

carry out other basic functionality on the system 

Maid’s CODE

, code 14, allows the system to be disarmed by this 

code if the system was armed with the maid’s code 

Duress CODE

, code 15, sends a duress signal to the monitoring 

company if used to arm or disarm the system 

ADD or CHANGE USER CODE 

1.

 

Hold [*] till BEEP, then [MASTER CODE] [*] [USER No.] [*] 
[NEW CODE] [*],[USER No.] [*] [NEW CODE] [*]... continue 
until all codes are entered then [#] to exit 

Note: User No. 1 = Master Code, No. 14 = Maid’s Code and No. 15 
= Duress Code 
 