ELECTRONIC BI-STABLE 

PULSE RELAY

Do not dispose of this device to a garbage bin with other unsorted waste! 

In  accordance  with  the  Waste  Electrical  and  Electronic  Equipment  Act 
any  household  electro-waste    can  be  turned  in  free  of  charge  and  in  any 
quantity to a collection point established for this purpose, as well as to the 
store in the event of purchasing new equipment (as per the old for new rule, 
regardless of brand). Electro-waste thrown in the garbage bin or abandoned 
in the

 

bosom of nature pose a threat to the environment and human health.

BIS-411i

230V

WARRANTY.

  The  F&F  products  are 

covered by a warranty of the 24 months   
from the date of purchase.  Effective only 
with  proof  of  purchase.  Contact  your 
dealeror  directly  with  us.  More 
information how to make a compliant can 
be found on the website:
www.fif.com.pl/reklamacje

5

9 0 8 3 1 2

5 9 8 3 8 1

- 1 -

Electronic bi-stable pulse relays BIS-411 230V enables the user to 
actuate lighting or other devices from various locations by means 
of control buttons in parallel connection.

PURPOSE

L

N

N

N/L

BIS

power supply

230V  AC

contact / current load AC-1

separated 1 C/O / 16A

control pulse

110÷265V AC <20mA

max current control buttons
activation delay

0.1÷0.2sec

signalling of supply

green LED

signalling of activation

red LED

working temperature

-25÷50°C

connection

screw terminals

tightening torque

0.4 Nm

dimensions

1 module (18mm)

Σ

5mA

power consumption
     standby

0,15W

     on

0,6W

2,5mm

fixing

 on the TH-35 rail

ingress protection

IP20

TECHNICAL DATA

WIRING DIAGRAM

11

12

1

3

6

L

N

11

12

1

3

6

L

N

control impulse: N

control impulse: L

SUPPLY

1-3

power relay: 100-265V AC

CONTROL INPUTS

6

control inputs

CONTACT

11

power input contact COM 

10

output: NC contact (passive)

12

output: NO contact (active)

D150203/150520

L

N

1

4

7

10

2

5

8

11

3

6

9

12

U

BIS-411

Example of relay 

connect

ion with

 N control pulse

Table of power

2000W

1000W

1250W

incandescent

fluorescent

halogen

The  above  data  are  indicative  and  will  heavily  depend  on  the 
design of a specific receiver (that is especially important for LED 
bulbs,  energy-saving  lamps,  electronic  transformers  and  pulse 
power  supply  units),  switching  frequency  and  operating 
conditions.
For more information visit www.fif.com.pl

energy-saving

LED

500W

250W

- 2 -

FUNCTIONING

The receiver is actuated by means of a current pulse triggered by 
pushing  any  bell  push  connected  to  the  relay.  The  receiver  is 
deactivated by another pulse or after a preset time. The relay does 
not “memorize” the position of the relay contact, i.e. in case of 
supply voltage decay and the subsequent return of supply voltage, 
the relay contact will be set in the off position. Such a solution 
prevents the automatic actuation of the receivers controlled that 
might occur without proper supervision after a long-lasting decay 
of supply voltage.

ATTENTION!

The  BIS-411  230V  is  compatible  with  bell 
pushes  equipped  with  fluorescent  lamps 
(

Σ

I<5mA).

ASSEMBLY

1. Turn OFF the power.
2. Put on the relay  on the rail in the switchgear box.
3.  Connect  the    power  cable  to  contacts  1-3  with  accordance 

choosen control option the relay (control impulse L or N).

4. The timers switching which are connect in parallel connect to 

contact 6 and to cable which is connect to contact 3.

5. The activated receiver connect in series to contacts 11-12.
6. By screwdriver set to switching OFF delay.

- 4 -

Relay version "i" is to pin adapted to cooperate with the receivers 
with  high  starting  current,  such  as  LED  fluorescent  lamps, 
ESL  fluorescent  lamps,  electronic  transformers,  discharge 
lamps, etc.