background image

INSTALLATION

RCI 6 SERIES

ELECTRIC STRIKES

  © 2019 dormakaba Canada Inc

www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]

IS6A-(B)

PCN18043 

R07-19GR-1

1.  Determine the vertical centerline of the door lock face 

and the horizontal centerline of the latch. 

IMPORTANT

: When determining the horizontal 

centerline observe the following: 

FOR MORTISE LOCKS

: Align the angled ramps of the lip 

bracket with the deadlock trigger of the mortise latch. 

FOR CYLINDRICAL LOCKS

: Align the center of the latch 

with the center of the strike opening.**

2.  Transfer both the horizontal and vertical centerlines to 

the doorframe.**

3.  Prepare the doorframe for cutting as shown in the 

appropriate drawing.

4.  If required, install the ‘no weld’ mounting brackets per 

page 4.

5.  Attach the strike faceplate to the lip bracket with the 

self-tapping screws provided. (It may be desirable to 

leave these screws slightly loose to facilitate insertion 

into the doorframe.

6.  Connect the incoming wiring from the power supply 

(see wiring instructions).

7.  Install the door strike in the doorframe using the 

screws provided.

E

K

B

A

F

M

G

C

G

D

R

X

CL

CL

M

RCI S6504 

Aluminum Frames, 1-3/16” Insert Depth

Modular 

AS65

 with 

B604

 faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL INCHES

METRIC

mm

 A  1-1/4  1.250  31.75
 B  4-7/8  4.875  123.83
 C  3-3/8  3.375  85.73
  D 1-3/16  1.188  30.16
 E  3/8 

.375  9.53

  F  1/8* 

.125*    3.18*

  G 1-11/16  1.688  42.86
    Vertical  Vertical Vertical
 X  C/L 

C/L 

C/L

   Door  Door  Door
 R  5/32  0.156  3.97
 K  4-1/8  4.125  104.78
 M 12-24  — 

Vertical Centerline

of Door**

E

K

B

A

F

M

G

C

G

D

R

X

CL

CL

M

RCI L6504

 Aluminum Frames, 1-1/16” Insert Depth

Modular 

AL65

 with 

B604

 faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL INCHES

METRIC

mm

 A  1-1/4  1.250  31.75
 B  4-7/8  4.875  123.83
 C  3-3/8  3.375  85.73
  D 1-3/32  1.094  27.78
 E  3/8 

.375  9.53

  F  1/8* 

.125*    3.18*

  G 1-11/16  1.688  42.86
    Vertical  Vertical Vertical
 X  C/L 

C/L 

C/L

   Door  Door  Door
 R  5/32  0.156  3.97
 K  4-1/8  4.125  104.78
 M 12-24  — 

Vertical Centerline

of Door**

NOTE

: Specifications subject to change without notice.

Dimension F

 is measured from face of mounting tab to face of frame.

** 

Dimension X

 on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps 

will be necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness 

to Dimension X to relocate the vertical centerline an appropriate distance on the frame.

Instructions

The RCI L65 Low Profile version accepts 1/2” or 5/8” latch 

projection (perfect for narrow stile aluminum frames). The 

RCI S65 Standard version is ideal when you require 3/4” 

latch projection.

UL 294 Performance Ratings:

Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I

Summary of Contents for RCI 6 Series

Page 1: ... 7 8 4 875 123 83 C 3 3 8 3 375 85 73 D 1 3 16 1 188 30 16 E 3 8 375 9 53 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertical X C L C L C L Door Door Door R 5 32 0 156 3 97 K 4 1 8 4 125 104 78 M 12 24 Vertical Centerline of Door E K B A F M G C G D R X C L C L M RCI L6504 Aluminum Frames 1 1 16 Insert Depth Modular AL65 with B604 faceplate MEASUREMENT FRACTIONAL INCHES DECIMAL INCHES ...

Page 2: ... 375 85 73 D 1 3 32 1 094 27 78 E 1 4 0 250 6 35 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertical X C L C L C L Door Door Door R 5 32 156 3 97 K 5 3 8 5 375 136 53 M 12 24 Vertical Centerline of Door F C G G A M B K E X R D C L M C L RCI L6507 Aluminum Wood Frames 1 1 16 Insert Depth Modular AL65 with B607 faceplate A 1 1 4 1 250 31 75 B 6 7 8 6 875 174 63 C 3 3 8 3 375 85 73 D 1 3 ...

Page 3: ...DECIMAL INCHES METRIC mm A 1 7 16 1 438 36 51 B 7 15 16 7 938 201 61 C 3 3 8 3 375 85 73 D 1 3 16 1 188 30 16 E 1 4 0 250 6 35 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertical X C L C L C L Door Door Door R 5 32 156 3 97 K 7 7 16 7 438 188 91 M 12 24 Vertical Centerline of Door X E K B R M D G G C A M RCI L6508 Aluminum Wood Frames 1 1 16 Insert Depth Modular AL65 with B608 faceplat...

Page 4: ...ace against the frame and mark the mounting hole locations Remove and drill a 3 16 hole in frame for each mounting tab and countersink the frame 3 Remove the tabs from the faceplate and install in the frame using the 12 24 x 3 8 machine screws supplied Tabs are zinc plated and drilled and tapped for this purpose 4 Make final electrical connections per wiring instructions and mount strike to the ta...

Page 5: ...ike Insert Keeper Fig 1 Fail Safe screw fully counter clockwise Fig 2 Fail Secure screw fully clockwise Fig 3 Lip bracket adjustment Wiring Instructions NOTE Overheated or Burnt Coils caused by incorrect input voltage wire harness combinations will not be covered under warranty For 12VDC or 12 24VAC input power connect RED and BLUE wires to positive connect BLACK and YELLOW wires to negative For 2...

Page 6: ...ge AC power supply and the 12V connector If this cannot be done a DC piezo buzzer can be installed Strike makes a buzzing sound Improper power supply Replace the power supply with a correct voltage DC power supply Insert has a burnt smell Improper voltage Confirm that you have the correct output voltage at the power supply Improper application A strike connected to an AC power supply will buzz unl...

Reviews: