background image

BLST-20

 

2D Handheld Barcode Scanner 

User Guide 

Summary of Contents for BLST-20

Page 1: ...BLST 20 2D Handheld Barcode Scanner User Guide ...

Page 2: ...Revision History Version Description Date V1 0 0 Initial release 2017 5 4 V1 0 1 Replacement charts 2017 5 11 V1 0 2 Modify font 2017 7 3 ...

Page 3: ... and maintenance 7 BLST 20Scanning gun appearance size 8 left view 8 front view 9 top view 10 code reading 11 Use setting code 12 Restore factory default 13 chapter two Communication 14 serial communication interface 14 Baud 15 USB port 16 USB HID KBW 16 Standard keyboard input mode 16 Keyboard simulation input character mode 16 Keyboard simulation input control character mode 17 Keyboard simulati...

Page 4: ...en intervals 31 stabilize the image 32 Sensitivity Setting 32 Continuous mode 33 Single read time limit 33 Read the interval length setting 33 Command trigger read mode 34 chapter four Lighting and aiming 35 Lighting 35 Aiming 36 Chapter Five Prompt output 37 start Close the mute 37 Read the successful note 37 Decoding successful sound volume Length is set 38 Read successful LED tips 38 Chapter Si...

Page 5: ...5 Allow Forbidden to read EAN 8 46 Sets whether to transfer check bits 46 Set whether or not to read 2 additional codes 46 Set whether or not to read 5 bits plus code 47 Setting whether to extend the result EAN 13 48 EAN 13 48 Restore Defaults 48 Allow Forbidden to read EAN 13 48 Sets whether to transfer check bits 49 Set whether or not to read 2 additional codes 49 Set whether or not to read 5 bi...

Page 6: ...o read Interleaved 2 of 5 58 Sets whether to transfer check bits 58 ITF 6 60 Restore Defaults 60 Allow Forbidden to read ITF 6 60 ITF 14 61 Restore Defaults 61 Allow Forbidden to read ITF 14 61 Matrix 2 of 5 European Matrix 2 of 5 62 Restore Defaults 62 Allow Forbidden to read Matrix 2 of 5 62 Test set 62 Industrial 25 63 Restore Defaults 63 Allow Forbidden to read Industrial 25 63 Sets whether to...

Page 7: ...I Plessey 75 Restore Defaults 75 Allow Forbidden to read MSI Plessey 75 Test set 75 RSS 14 76 Restore Defaults 76 Allow Forbidden to read RSS 14 76 AI 01 Character send Settings 77 RSS Limited 77 Restore Defaults 77 Allow Forbidden to read RSS Limited 77 AI 01 Character send Settings 78 RSS Expand 78 Restore Defaults 78 Allow Forbidden to read RSS Expand 78 PDF417 79 Restore Defaults 79 Allow Forb...

Page 8: ...pendix 84 Appendix A Default setting table 84 Appendix B AIM ID List 91 Appendix C Code ID List 93 Appendix D ASCII Code table 94 Appendix E Parameter setting example 98 Single read length setting method 98 Read the interval length setting method 98 Stable image length setting method 98 Custom sensitivity setting method 98 Appendix F Data Code 99 Appendix G Save or cancel 101 ...

Page 9: ...T 20 can easily read the paper plastic card LCD and other printing media and display media bar code the performance is strong Its fully integrated design is very easy to embed in various product applications About this guide This guide mainly provides various function setting instructions for BLST 20 products By scanning the setting function bar code in this guide the function parameters of BLST 2...

Page 10: ...2 BLST 20 Wired scanning gun appearance The image below shows the main components of the BLST 20 wired scanner gun Indicator definition Green LED Decoding success indicator ...

Page 11: ... 232 Input 6 CTS I O CTS 7 NC NC NC 8 GND P GND 9 D I O USB 10 D I O Communication port must be connected to a host to operate The host can be a PC a POS machine or an intelligent terminal with any one of the USB RS 232 interfaces USB The USB port on the host RS 232 The RS 232 interface on the host ...

Page 12: ...4 Connect BLST 20 to host USB cable connection 1 Connect the device interface end RJ45 interface of USB cable to BLST 20 2 Connect the host interface USB port of the USB cable to the host ...

Page 13: ...nected 1 Connect the device interface end RJ 45 interface of the RS 232 data line to the BLST 20 2 Connect the host interface of the RS 232 data line RS 232 interface to the host 3 Connect the RS 232 data cable to the power adapter ...

Page 14: ...ole and press it hard 3 Gently pull out the end of the data line and the scanning gun and pull the needle out of the hole 4 Unplug one end of the data cable from the host Boot Hibernate Shutdown Restart Boot Connect the cable gun to the host The BLST 20 cable gun is switched on automatically and in a dormant state factory setting Hibernate When the scan gun is over a certain period of time without...

Page 15: ...y improper maintenance avoid wear or scratch read hard and rough object window Use a brush to remove stains from the window please use soft cloth to clean the window such as glasses cleaning cloth it is forbidden to spray window any liquid it is prohibited to use any other than the clean water cleaner ...

Page 16: ...8 OY20 Scanning gun appearance size Left view ...

Page 17: ...9 Front view ...

Page 18: ...10 Top view ...

Page 19: ... appear 3 Align the red focusing spot with the barcode center move the scanning gun and adjust the distance between it and the bar code to find the best read distance 4 When the sound is heard and the white light is extinguished the reading code is successful The scanning gun transmits the decoded data to the host Attention In the reading process you will find the distance between the scanning gun...

Page 20: ...ctory default setting is do not send the set code information when the code information is not sent to the host By reading the bar code that sends the set code information the reader will send the set code information to the host This bar code function is temporary the next time the chip on the power then restore to the default setting ...

Page 21: ...tore factory default function carefully After reading this set code the current parameter setting will be lost and the default value will be replaced by the factory Factory default parameters and functions can be seen in the appendix Restore factory default ...

Page 22: ...tc The OY20 scanner provides the rs 232 level interface which can be connected directly to the PC s serial port When using a serial communication interface the scanner and the host device must match the configuration of the communication parameters to ensure that the communication is smooth and the content is correct The scanner s default serial communication parameters are shown in the following ...

Page 23: ...15 Baud Rate Baud Rate is a unit of bit SEC bps bits per second The optional configuration parameters are shown in the table below 9600 1200 19200 2400 38400 4800 57600 14400 115200 ...

Page 24: ...imulation input character mode In order to enable the reading engine to enter any ASCII character in any language system hexadecimal value at 0x00 0xFF the virtual keyboard can be set to keyboard simulation input character mode When you use this combination to output characters because the output is more data the speed will slow down In the switch to the keyboard simulation input character model i...

Page 25: ... into a control function key The input of the control function key in the virtual keyboard is as follows 1 Hold down the Ctrl button 2 Accordingtothespecifiedcontrolfunctionkey thecorrespondingrelationbetweenASCIIvalue and control function key can be seen in the next page of keyboard simulation input control character corresponding table 3 Release the Ctrl button and the control function key Keybo...

Page 26: ...character corresponding table ASCII Value HEX Function Key ASCII Value HEX Function Key 00 2 10 P 01 A 11 Q 02 B 12 R 03 C 13 S 04 D 14 T 05 E 15 U 06 F 16 V 07 G 17 W 08 H 18 X 09 I 19 Y 0A J 1A Z 0B K 1B 0C L 1C 0D M 1D 0E N 1E 6 0F O 1F ...

Page 27: ...ferent languages correspond to different keyboards symbols and so on The scanner can be used as a keyboard for different countries and the default is the American English keyboard AmerEnglish Belgium Brazil Canada Czechoslovakia Denmark Finland France ...

Page 28: ...20 Germany Austria Greece Hungary Israel Italy Latin America South America Netherlands Norway Poland Portugal ...

Page 29: ...21 Rumania Russia Slovakia Spain Sweden Swit Turkey_1 Turkey_2 England Japan ...

Page 30: ...essage when this error is generated When the no prompt is selected there will be no error messages When you select prompt if the barcode information contains unknown characters there will be an error message Hint Don t tip Interkey delay setting The keystroke time interval of the virtual keyboard continuous keystroke operation the time interval is the last time the key is released to the next butt...

Page 31: ...ersion is not affected by the current state of Caps Lock on the host keyboard close Caps Lock open Caps Lock Attention This function is invalid if the keyboard emulation input character mode or mandatory letter case conversion function is used Example After this function is opened the reading engine reads the bar code of AbC and the host will get AbC ...

Page 32: ...he letters in the output data are uppercase or lowercase and all are converted to uppercase letters If it is set to all lowercase all the letters in the output data are uppercase or lowercase and all lowercase Don t convert All the capital All lowercase Example Set all lowercase when the content data is read as AbC bar code the host will get the AbC keyboard input ...

Page 33: ...ing to the large keyboard Simulation of the numeric keypad function by host keypad Num Lock status the influence of if the host small keyboard Num Lock status to close Num Lock lights decoding data still press the keyboard keys corresponding value output If the Num Lock state of the host keypad is turned on the Num Lock lamp is lit the decoded data is output by the key value corresponding to the n...

Page 34: ...al port communication mode This feature requires that the driver be installed on the host USB virtual serial port USB DATAPIPE When the scanner USES the USB communication interface the host application USES the serial communication mode to receive the data then the scanner can be set to the USB virtual serial port communication mode This feature requires that the driver be installed on the host US...

Page 35: ...ll the driver communication speed than analog keyboard interface and traditional RS 232 interface are much faster Attention USB HID POS interface does not need to install custom driver However the HID interface needs to be installed in Windows 98 system When the device is first plugged in Windows 98 will request an installation driver All HID interfaces are driven by standards provided by the oper...

Page 36: ... reference www USB org Get scan data After scanning and decoding a bar code the device sends the following input message Bit Byte 7 6 5 4 3 2 1 0 0 ID 0x02 1 Barcode data length 2 57 Barcode data 1 56 58 60 AIM ID 61 62 reserve 63 DCPH continue Send data to the device The upper machine sends commands to the device using the Output message below All setup commands are available Bit Byte 7 6 5 4 3 2...

Page 37: ...by USB implementer Forum USB application vendor BBS The new world auto id company s manufacturer ID VID is 1EAB hexadecimal The second number is PID device ID Each interface type assigns a PID number Equipment Name Interface Type PID Hexadecimal PID Decimal BLST 20 USB HID KBW 1A03 6659 USB COM Port Emulation 1A06 6662 USB HID POS 1A10 6672 ...

Page 38: ...r level is maintained it will continue to be photographed until it is successful When the trigger level is withdrawn or read more than a single read length limit the filming will be aborted When the reading is successful the scanner outputs the edited content through the communication interface To initiate a new trigger read the host needs to undo the trigger level first with a distance of 20ms an...

Page 39: ...maximum length of time that the reading engine is allowed to continue to collect and identify before it is read successfully After a successful reading or a single reading timeout the reading engine will enter the interval that does not capture reading The length of the single read length is 0 1 25 5 seconds and the step length is 0 1 second When set to 0 the reading time is infinite The default t...

Page 40: ...k in automatic sensing mode and to determine the degree of change of the reading state when the monitoring scene changes The higher the sensitivity the smaller the change in the scene Conversely the lower the sensitivity the larger the scene changes HIGH Medium Low Custom The sensitivity level setting method in the induction mode can be set to a total of 255 grades the smaller the number and the h...

Page 41: ...ode Single read time limit In continuous mode it refers to the maximum duration of the acquisition and identification before the success of the reading and after the timeout it will enter the interval of not collecting the reading The reading time is 100ms and it can be set to 0 1 25 5s When set to 0 it stands for an infinite length of time Set way to refer to appendix E Single read time limit Rea...

Page 42: ...control the trigger reader to decode Command trigger read In the command trigger mode the scanner can set the length of the reading time and the reading time can be set to 0 1 25 5s When set to 0 it means an infinite length of time Set the length of the read code ...

Page 43: ...t of leds specially equipped to provide auxiliary illumination for shooting and reading The beam will illuminate the target and improve the adaptability of reading performance and weak ambient light The lighting group lights up at the time of shooting and other time goes out ...

Page 44: ...is projected onto the target and the scanner is aiming to read the target which makes it easier to read the desired target Ordinary the aiming device will light up the projection of the image during the shooting process and the other time will be extinguished Constant light the aiming device has been in working state and continuously projected the figure No aim the sighting device has been put out...

Page 45: ...osed Read the successful note After the scanner is successfully read the PWM signal can be output to drive the external buzzer circuit to make a sound The sound signal can be set to be turned off or allowed to output and the type and volume of the sound can be changed by setting The corresponding Settings can be set by the following Settings Open decoding sound Close decoding sound ...

Page 46: ...ume pitch setting Low frequency sound Intermediate frequency sound High frequency sound Length 40 ms Length 80 ms Length 120 ms Read successful LED tips Open the decoding successful LED prompt Close the decoding successful LED prompt ...

Page 47: ...o as adding prefixes suffixes and packaging Data editing mainly has the following operations before decoding data can be added AIM ID Code ID prefix can be added after decoding data suffix To all of the above operations can be added after the completion of terminator After configuration the device can output barcode information in the following format F S Code ID AIM ID end character except the DA...

Page 48: ... can add this identification code to the bar code data which is the AIMID prefix Ban AIM ID OUT Allow AIM ID OUT CODEID Prefix In addition to the AIM prefix which can be used to identify different barcode types users can also use CODEID prefixes to identify barcode types Forbidden to add CODEID prefix AllowAdditions CODEID prefix There are two types of CODEID output the original schema the visible...

Page 49: ...tor The end of the suffix is used to mark the end of a complete data message The end character suffix is prohibited After adding the terminator CR After adding the terminator CR LF After adding the terminator TAB ...

Page 50: ...not used to improve the performance of the reader List style Do not read all barcodes Read the no bar code the reader will only be able to read the Settings code all bar codes except the set code will not be able to read Do not read all barcodes Allow to read all barcodes Read allow to read all barcode the reader will read all readable barcode Allow to read all barcodes Allow to read all one dimen...

Page 51: ...d barcodes Allow to read all 2d barcodes It is forbidden to read all 2d barcodes It is forbidden to read all 2d barcodes Code 128 Restore Defaults After reading the set Code the following parameter Settings for Code 128 will be restored to the default state of the factory Restore the Code128 default value ...

Page 52: ...UCC EAN 128 Restore Defaults After reading the set code the following parameter Settings for UCC EAN 128 will be restored to the default state at the factory Restore UCC EAN 128 default values Allow forbid to read UCC EAN 128 Allowed to read UCC EAN 128 Forbidden to read UCC EAN 128 ...

Page 53: ...he default state at the time of delivery Restore AIM 128 by default Allow forbid to read AIM 128 Allowed to read AIM 128 Forbidden to read AIM 128 EAN 8 Restore Defaults After reading the set code the following parameters of the EAN 8 will be restored to the default state at the factory Restore the EAN 8 default value ...

Page 54: ...est bit to verify the correctness of all 8 characters Transfer check bit No check bits are sent Set whether or not to read two additional codes Two extension code refers to the ordinary barcode attach 2 digits barcode with two extension code is illustrated below barcode among them the blue line on the left box for ordinary barcode on the right side of the red wire frame for two extension yards ...

Page 55: ...de Five extension code refers to the ordinary barcode attach 5 digit barcode below the barcode of the extension to take five yards the blue line on the left box for ordinary barcode on the right side of the red wire frame for five extension code Don t read Allowed to read ...

Page 56: ...o not extend barcode information into 13 ean 13 Expand the bar code information to 13 bits plus 0 EAN 13 Restore Defaults After reading the set code the following parameters Settings for ean 13 are restored to the default state at the factory Restore the EAN 13 default value Allow forbid to read EAN 13 Allowed to read EAN 13 Forbidden to read EAN 13 ...

Page 57: ...characters Transfer check bit No check bits are sent Set whether or not to read two additional codes Two extension code refers to the ordinary barcode attach 2 digits barcode with two extension code is illustrated below barcode among them the blue line on the left box for ordinary barcode on the right side of the red wire frame for two extension yards Don t read Allowed to read ...

Page 58: ... the extension to take five yards the blue line on the left box for ordinary barcode on the right side of the red wire frame for five extension code Don t read Allowed to read ISSN Restore Defaults After reading the set code the following parameter Settings for ISSN will be restored to the factory default state Restore the ISSN default value ...

Page 59: ...o read ISSN ISBN Restore Defaults After reading the set code the following parameters of the ISBN will be restored to the default state when it leaves the factory Restore the ISBN default value Allow forbid to read ISBN Allowed to read ISBN Forbidden to read ISBN ...

Page 60: ...store Defaults After reading the set code the following parameter Settings for UPC E will be restored to the default state at the time of delivery Restore UPC E default values Allow forbid to read UPC E Allowed to read UPC E Forbidden to read UPC E ...

Page 61: ...aracters Transfer check bit No check bits are sent Set whether or not to read two additional codes Two extension code refers to the ordinary barcode attach 2 digits barcode with two extension code is illustrated below barcode among them the blue line on the left box for ordinary barcode on the right side of the red wire frame for two extension yards Allowed to read Don t read ...

Page 62: ...on the left box for ordinary barcode on the right side of the red line box extension for five yards Allowed to read Don t read Set whether to send system character 0 Transfer system character 0 No system character 0 Setting whether the result is extended UPC A The chip can expand the decoding results of the UPC E type barcode to the UPC A type bar code according to the standard algorithm ...

Page 63: ...o UPC A UPC A Restore Defaults After reading the set code the following parameters of UPC A will be restored to the default state when it leaves the factory Restore UPC A default values Allow forbid to read UPC A Allowed to read UPC A Forbidden to read UPC A ...

Page 64: ...haracters Transfer check bit No check bits are sent Set whether or not to read two additional codes Two extension code refers to the ordinary barcode attach 2 digits barcode with two extension code is illustrated below barcode among them the blue line on the left box for ordinary barcode on the right side of the red wire frame for two extension yards Allowed to read Don t read ...

Page 65: ...the extension to take five yards the blue line on the left box for ordinary barcode on the right side of the red line box extension for five yards Allowed to read Don t read Set whether to send system character 0 The first byte of UPC A barcode is the system character whose value is fixed to 0 Transfer system character 0 No system character 0 ...

Page 66: ...e last byte of the data The check digit is the value calculated by all data except the parity bit to verify the correctness of the data Set to uncheck the reader will normally transmit all barcode data Is set to check but not send check digit read editor according to the barcode to check the last one data if check through the transmission except the last one parity bit of normal data the checksum ...

Page 67: ...of code digits the parity bits are included in the code and if the encoding is odd then 0 is added before the first digit Check bits are generated automatically when code is made No parity Verify and pass the validator Verify but do not pass the checkmark ...

Page 68: ...g parameter Settings on itf 6 will be restored to the default state at the time of delivery Restore the itf 6 default value Allow forbid to read ITF 6 Forbidden to read ITF 6 Allow to read itf 6 and pass the validator Allow to read itf 6 but do not pass the validator ...

Page 69: ...arameter Settings on itf 14 will be restored to the default state at the time of delivery Restore the itf 14 default value Allow forbid to read ITF 14 Forbidden to read ITF 14 Allow to read itf 14 and pass the validator Allow to read itf 14 but do not pass the validator ...

Page 70: ...the data The checkmark is the value calculated from all data to verify the correctness of the data Therefore the reader will transmit all barcode data as uncheckable Set to check but not transfer check operator read apparatus based on barcode last one do check the data if check through the normal data transmission in addition to the calibration operator check failure will be prompted to read the c...

Page 71: ...al 25 Restore Defaults After reading the set code the following parameter Settings for Industrial 25 will be restored to the default state at the factory Restore the Industrial 25 default value Allow forbid to read Industrial 25 Allowed to read Industrial 25 Forbidden to read Industrial 25 ...

Page 72: ...to check but not send check digit chip will according to the bar code to check the last one data if check through the transmission except the last one parity bit of normal data check failure will not send the barcode content Set to check and transmit check digit chip will according to the bar code to check the last one data if check through the check digit as normal data together with the last one...

Page 73: ... character of the data Parity is the value calculated from all data to verify that the data is correct Set to uncheck the chip will transmit all barcode data normally Set to check but not send check digit chip will according to the bar code to check the last one data if check through the transmission except the last one parity bit of normal data check failure will not send the barcode content Set ...

Page 74: ...checkmark Code 39 Restore Defaults After reading the set Code the following parameter Settings for Code 39 will be restored to the default state at the time of delivery Restore Code 39 defaults Allow forbid to read Code 39 Allowed to read Code 39 Forbidden to read Code 39 ...

Page 75: ...eckmark is the value calculated from all data to verify the correctness of the data Therefore the reader will transmit all barcode data as uncheckable Set to check but not transfer check operator read apparatus based on barcode last one do check the data if check through the normal data transmission in addition to the calibration operator check failure will be prompted to read the code Set to chec...

Page 76: ...ction of reading full ASCII characters by setting Close all ASCII literacy Open full ASCII literacy Codabar Restore Defaults After reading the set code the following parameter Settings for Codabar will be restored to the default state of the factory Restore the Codabar default Allow forbid to read Codabar Allowed to read Codabar Forbidden to read Codabar ...

Page 77: ...ne do check the data if check through the normal data transmission in addition to the calibration operator check failure will be prompted to read the code Set to check and transfer check operator is read apparatus based on barcode last one do check the data if check through the calibration operator as normal data together with the last one check failure will be prompted to read the code No parity ...

Page 78: ... with ABCD ABCD Start and terminate characters with ABCD TN E Code 93 Restore Defaults After reading the set Code the following parameter Settings for Code 93 will be restored to the default state of the factory Restore Code 93 defaults Allow forbid to read Code 93 Allowed to read Code 93 Forbidden to read Code 93 ...

Page 79: ... normal data transmission in addition to the calibration operator check failure will be prompted to read the code Set to check and transfer check operator is read apparatus based on barcode last one do check the data if check through the calibration operator as normal data together with the last one check failure will be prompted to read the code No parity Verify but do not pass the checkmark Veri...

Page 80: ...can be the last 1 or 2 characters of the data Parity is the value calculated from all data to verify that the data is correct Therefore the reader will transmit all barcode data as uncheckable No parity A check MOD11 Two calibration MOD11 MOD11 Two calibration MOD11 MOD9 MOD11 Single check Len 10 MOD11 MOD11 Double check Len 10 MOD11 Single check Len 10 MOD11 MOD9 Double check Len 10 ...

Page 81: ...Defaults After reading the set code the following parameter Settings for Plessey will be restored to the default state when they leave the factory Restore the Plessey default value Allow forbid to read Plessey Allowed to read Plessey Forbidden to read Plessey ...

Page 82: ...a check digit it can be the last 1 or 2 characters of the data Parity is the value calculated from all data to verify that the data is correct Therefore the reader will transmit all barcode data as uncheckable No parity Verify and pass the validator Verify but do not pass the checkmark ...

Page 83: ...w forbid to read MSI Plessey Allowed to read MSI Plessey Forbidden to read MSI Plessey Test set The msi plessey barcode data does not include a check digit and if there is a check digit it can be the last or two characters of the data Parity is the value calculated from all data to verify that the data is correct Therefore the reader will transmit all barcode data as uncheckable No parity A check ...

Page 84: ...sent Send check bit RSS 14 Restore Defaults After reading the set code the following parameter Settings for the rss 14 are restored to the default state at the time of delivery Restore the rss 14 default Allow forbid to read RSS 14 Allowed to read RSS 14 Forbidden to read RSS 14 ...

Page 85: ...RSS Limited Restore Defaults After reading the set code the following parameter Settings for the rss 14 are restored to the default state at the time of delivery Restore RSS Limited default values Allow forbid to read RSS Limited Allowed to read RSS Limited Forbidden to read RSS Limited ...

Page 86: ...S Expand Restore Defaults After reading the set code the following information about the rss expand parameter setting will be restored to the default state at the factory Resume RSS Expand the default Allow forbid to read RSS Expand Allowed to read RSS Expand Forbidden to read RSS Expand ...

Page 87: ...tored to the default state of the factory Restore PDF417 default value Allow forbid to read PDF417 Allowed to read PDF417 Forbidden to read PDF417 Data Matrix Restore Defaults After reading the set code the following parameter Settings for DM are restored to the default state at the factory Restore DM default ...

Page 88: ... mirror image Rectangle code recognition Settings Rectangular code this is the rectangular Data Matrix bar code The Data Matrix bar code has two formats Square code of the same length and width module 10 10 12 12 144 144 rectangular code with inconsistent length and width 6 16 6 14 14 22 Identification rectangular code The rectangular code is not recognized ...

Page 89: ... restored to the default state of the factory Restore the QR default value Allow forbid to read QR Allowed to read QR Forbidden to read QR Set the allow disable read Micro QR This setting is valid when you are allowed to read QR Micro QR decoding is allowed Micro QR decoding is prohibited ...

Page 90: ...ticular bar code appears an error The bar code data is missing and the bar code can be checked If not set up to empty all interceptions b The is displayed before and after the data and Code39 does not transmit the start and end c If the barcode data is a the reading data is a then open Code to open the full ASCII reading function d If all barcode errors occur it will be displayed as the bar code d...

Page 91: ...Check whether the equipment is on power b Send To the device if the device answers the device communication is normal can send setting command setting lamp and aiming lamp mode Q Carriage return setting A See the end character set in the manual ...

Page 92: ... between Don t delay HID KBW Unknown character prompt tone ON Alt array output ASCII character Off Control character escape combination control key Off Analog numeric keypad Off Mode constan Default read mode Manual mode Other options continuous mode inductive mode command trigger mode Induction model Single read length 3000ms Parameters that are Shared by manual mode inductive mode and continuous...

Page 93: ...oot prompt OUT Decode the successful prompt Hint Allow Prompt type Intermediate frequency sound Sound length 80ms Set the code to read the prompt Allow prompt Decoding successful LED prompt Open Data Editor The prefix to add Not add The prefix content None AIM ID Not add Code ID Not add Terminator Add Terminator CR ENTER ...

Page 94: ... 127 Lmin 1 EAN 8 Read Allow Output check OUT 2 Extension code Don t read 5 Extension code Don t read There must be an extension code Toefl Ielts Extended to EAN 13 did not grow EAN 13 Read Allow Output check OUT 2 Extension code Don t read 5 Extension code Don t read ISSN Read Not allow 2 Extension code Don t read 5 Extension code Don t read ...

Page 95: ...nsion code Don t read Extend to UPC A did not grow Output system character 0 OUT UPC A Read Allow Output check OUT 2 Extension code Don t read 5 Extension code Don t read There must be an extension code Toefl Ielts Output leading character 0 OUTPUT NO Interleaved 2 of 5 Read Allow Check Don t check Output check OUT Lmax 100 Lmin 6 ITF 6 Read Not allow Output check OUTPUT NO ...

Page 96: ...Lmin 6 Industrial 2 of 5 Read Allow Check Don t check Output check character OUTPUT NO Lmax 127 Lmin 6 Standard 2 of 5 Read Allow Check Don t check Output check character OUTPUT NO Lmax 127 Lmin 6 Code 39 Read Allow Check Don t check Output check character OUTPUT NO Output start and end characters OUTPUT NO Support Full ASCII Not supported Lmax 127 Lmin 1 ...

Page 97: ...end format ABCD ABCD Lmax 127 Lmin 1 Code 93 Read Allow Check Request validation Output check character OUTPUT NO Lmax 127 Lmin 3 GS1 Databar Read Allow Output AI 01 characters OUT Code 11 Read Allow Check ONE MOD11 Output check character OUTPUT NO Lmax 127 Lmin 2 Plessey Read Allow Check Request validation Output check character OUTPUT NO Lmax 127 Lmin 1 ...

Page 98: ...d Allow Check ONE MOD10 Output check character OUT Lmax 127 Lmin 2 PDF417 Read Allow Lmax 2710 Lmin 1 QR Code Read Allow Micro QR Allowed to read Lmax 7089 Lmin 1 Data Matrix Read Allow Rectangular code Read Mirror the barcode Read Lmax 3116 Lmin 1 ...

Page 99: ... data plus 2 5 Addon Interleaved 2 of 5 I0 Don t checky I1 Check and output check characters I3 Verify but do not output the check character ITF 6 I1 Output check character I3 Does not output the check character ITF 14 I1 Output check character I3 Does not output the check character Deutsche 14 Deutsche 12 X0 Matrix 2 of 5 X1 Don t check X2 There is a checksum output check character X3 There is a ...

Page 100: ... check character Code 93 G0 No special designation is available Code 11 H0 MOD11 Single character check and output check character H1 MOD11 MOD11Double character check and output check character H3 Check but do not output the check character H8 MOD11 MOD9Double character check and output check character H9 Don t check Plessey P0 No special designation is available MSI Plessey M0 MOD10 Check and ou...

Page 101: ...ved 2 of 5 8 H 0x48 ITF 14 9 I 0x49 ITF 6 10 J 0x4A Code 39 13 M 0x4D Codabar 15 O 0x4F Standard 2 of 5 16 P 0x50 Code 93 17 Q 0x51 AIM 128 21 U 0x55 MSI Plessey 22 V 0x56 ISBN 23 W 0x57 Industrial 2 of 5 24 X 0x58 Matrix 2 of 5 25 Y 0x59 RSS 14 26 Z 0x5A RSS Limited 27 0x5B RSS Expanded 28 0x5C Code 11 29 0x5D Plessey 30 0x5E ISSN 31 _ 0x5F PDF417 32 0x60 QR 33 a 0x61 Data Matrix 35 c 0x63 ...

Page 102: ...eed 0b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK Negative Acknowledgment 16 22 SYN Synchronous Idle 17 23 ETB End of Trans Block 18 24 CAN Cancel 19 25 EM End of Medium 1a 26 SUB Substitut...

Page 103: ...ollar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Right Closing Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sign ...

Page 104: ...5 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket ...

Page 105: ...100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left Opening Brace 7c 124 Vertical Bar 7d 125 Right Closing Brace 7e 126 Tilde 7f 127 DEL Delete ...

Page 106: ...ollowing bar code in order 1 Read change the interval between reading and reading 2 Read the data code 5 and 0 3 Read save Stable image length setting method Example set the stable image length to 5 0s please read the following bar code in order 1 Read modify stable image length 2 Read the data code 5 and 0 3 Read save Custom sensitivity setting method Example set the sensitivity level to 5 Please...

Page 107: ...99 Appendix F Data Code 0 9 0 5 1 6 2 7 3 8 4 9 ...

Page 108: ...A F A B C D E F ...

Page 109: ...s read and read data in turn 1 2 3 then if read cancel the previous read a data the number 3 will cancel the last read if you read cancel the previous read a string of data will cancel the data read into 123 if read cancel the current Settings to set code connected to cancel but the equipment is still in the state of startup Settings Save Cancels a parameter of the current setting Cancels all para...

Reviews: