Summary of Contents for Theatre Sport 150

Page 1: ......

Page 2: ...te for Color Filter Barn Door Installation 5 4 How To Set The Unit 6 4 1 Control Panel 6 4 2 Main Functions 7 5 Control By Universal DMX Controller 12 5 1 DMX512 Connection 12 5 2 Address Setting 13 5 3 DMX512 Configuration 13 6 Troubleshooting 14 7 Fixture Cleaning 15 1L ...

Page 3: ...ilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock Minimum ambient temperature TA 0 Maximum ambient temperature TA 4...

Page 4: ... repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center if needed Disconnect the mains power if the fixture is has not been used for a long time DO use the original packing materials before transporting it again DO NOT look directly at the light while the LED is on DO NOT start on the u...

Page 5: ...90 CQS WW 94 CW 91 TLCI WW 96 CW 96 Control DMX Channel 2 3 Channels Mode Control Mode DMX Art Net Primary Secondary Manual Firmware Upgrade Update via DMX link Construction Display LCD display Data In Out 5 pin XLR Power In Out Power Connector in out Protection Rating IP20 Features Motorized linear zoom system zoom range 14 55 4 dimming curves 2 optional dimming speed 0 100 smooth dimming Low noi...

Page 6: ...00 1175 575 14 55 WW 6240 2380 1215 595 55 Lux CW 2240 820 420 205 WW 2000 840 430 210 3 The Plate for Color Filter Barn Door Installation Fig 1 At first please push the Lock Cap button by hand as the arrow and move away the Lock as the arrow Then insert the Plate for Color Filter into the inside slot from topside 5L ...

Page 7: ...ock Note the Barn Door must be fastened into the inside of the lock s hook then flip down the lock cap again as arrow 4 How To Set The Unit 4 1 Control Panel 1 DISPLAY Shows the various menus and the selected functions 2 LED PRIMARY On Primary Mode SECONDARY On Secondary Mode DMX On DMX input present 6L ...

Page 8: ...512 link use 5 pin XLR cable to link the unit together 10 FUSE T 5A Used to protect the unit from damage of the over current 11 ETHERNET Connect with the multimedia and use software to control the units via ArtNet 4 2 Main Functions Turn on the unit press the MENU button into menu mode and press the UP DOWN button until the required function is shown on the monitor Select the function by the ENTER...

Page 9: ...tup or Channel Mode DMX Address Select DMX Address press the ENTER button to confirm Use the UP DOWN button to adjust the DMX address from 1 to 511 510 Once the address has been selected press the ENTER button to save Hold and press the MENU button about one second or wait for 30 seconds to exit the menu mode 8L ...

Page 10: ...Mode press the ENTER button to confirm Use the UP DOWN button to select the 2 CH or 3 CH Once selected press the ENTER button to save Hold and press the MENU button about one second or wait for 30 seconds to exit the menu mode Dimmer Speed Select Dimmer Speed press the ENTER button to confirm Use the UP DOWN button to select Smooth dimmer speed smooth or Fast dimmer speed fast Once selected press ...

Page 11: ... button to select Pri Sec Blackout or Hold Once selected press the ENTER button to save Hold and press the MENU button about one second or wait for 30 seconds to exit the menu mode Display Setting Select Display Setting press ENTER button to confirm Use the UP DOWN button to select Contrast Ratio Backlight Auto Off Invert Display or Language Contrast Ratio Select Contrast Ratio press the ENTER but...

Page 12: ...to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Fixture Information Select Fixture Information press the ENTER button to confirm use the UP DOWN button to select Fixture Time or Firmware Version Fixture Time Select Fixture Time press the ENTER button to confirm and the running time of the fixture will show on the display Press the MENU button ...

Page 13: ...from the output of the unit to the input of the next unit The cable cannot be branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 Eac...

Page 14: ... the present address will blinking the display use the UP DOWN button to adjust the address from 001 to 512 press the ENTER button to store Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 2 ...

Page 15: ...t and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED to see if it can be light up or not B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if they are linked properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX pola...

Page 16: ...ition 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth and use normal glass to clean liquid Always dr...

Page 17: ...16L ...

Page 18: ...17L ...

Page 19: ...18L ...

Page 20: ...Innovation Quality Performance ...