background image

Fibrlok

II Splice/Holder 2539 Instructions

Use 99% pure reagent-grade isopropyl alcohol to clean the fibers and other components. When splicing 

any cable containing grease, ensure that all grease is wiped away and the buffer coating and fiber are 

thoroughly cleaned with isopropyl alcohol.

The 3M™ Fibrlok™ II Splice/ Holder 2539 enables fast, on-site installation of Fiber-to-the Premises 

(FTTP) connections with a built-in actuation feature. 3M Fibrlok II Universal Optical Splices provide 

permanent mechanical splices using either single-mode or multimode 125

μ

m fibers with any combination 

of 250

μ

m and 900

μ

m coating diameters.

1.0   General  

1.1

2.0  Safety and Helpful Hints

Note: Carefully follow safety, health and environmental information on the label or MSDS for isopropyl 
alcohol. Storage, use and disposal of isopropyl alcohol per your company health, safety and environmental 
instructions.

Carefully follow safety, health and environmental information on 3M Fibrlok II Splice label or             

Material Safety Data Sheet.       

The gel inside the splice may cause minimal eye irritation. Avoid eye contact. Wash hands before eating or 

smoking. Immediately flush eyes with plenty of water while holding eyelids open. Do not view fiber ends if 

they are illuminated with a laser.

2.2

2.1

1.2 All 2529 universal optical fiber splices are gray in color

and are marked with 3M Fibrlok II logo on the splice cap.

Summary of Contents for Fibrlok II 2539

Page 1: ...50μm and 900μm coating diameters 1 0 General 1 1 2 0 Safety and Helpful Hints Note Carefully follow safety health and environmental information on the label or MSDS for isopropyl alcohol Storage use and disposal of isopropyl alcohol per your company health safety and environmental instructions Carefully follow safety health and environmental information on 3M Fibrlok II Splice label or Material Sa...

Page 2: ...r several seconds onto the surface of its final location Lift the buffer clamps at both ends of the splice holder and lift the actuation lever to the up position Note The 3M Fibrlok II Splice Holder is designed for 900μm tight buffer and 250μm primary coated fiber To splice 900μm loose tube semi tight or release layered fiber remove the 900μm coating within the last four inches or more from the fi...

Page 3: ...iber into the splice the mark on the first fiber should move outwards 1 8 inch 3mm showing the fiber ends are in contact If this is not observed one or both fibers has a bad short cleave Remove one fiber and re strip clean re cleave and insert back into the splice If contact is still not correct repeat procedure for second fiber 7 5 Note To prevent contamination never fully remove and re insert a ...

Page 4: ...low While the splice is still in the holder assembly lift the actuation lever and insert the cap removal tool over the splice cap Grasp both sides of the splice holder base and lift the cap up and off the splice while gently rocking lengthwise Replace the cap parallel to the top but raised about 1mm 0 04 inch as it snaps into place 7 8 Carefully reposition fiber Refer to section 7 0 for proper fib...

Reviews: