Chapter 6: Fault
ZoneDAS User Guide
Page | 41
The following table describes the labels on this screen.
Table 15
Fault > Past Alarms
LABEL
DESCRIPTION
Index
This is the index number for the past alarm.
Category
Select the system partition for which you wish to display past alarms.
•
mgmt - include alarms from the BU-MB.
•
eqpt- include
hardware
alarms from the BU-SD, BU-RF, RU-RF, RU-MB.
•
das - include
software
alarms from the BU-SD, BU-RF, RU-RF, RU-MB.
•
All - include all alarms from the entire ZoneDAS system.
Condition
This allows you to filter past alarms by condition. Enter the condition you want to
search for. See
for more information on the various alarm
conditions.
Severity
This allows you to filter past alarms by severity. Select the severity level of the past
alarm you want to search for. ZoneDAS then searches for all alarms of that severity
or higher. See
for more information on event severity.
Timestamp
This allows you to filter past alarms by time and date. Enter the day and time to filter
alarms by time of occurrence. For example, if you want to show past alarms from
January 22, 2019, you would type “2019-01-22”. If you want to see past alarms that
have occurred between 6pm and 7pm every day, you would type “18:” If you
follow that with 18, for “18:18”, you would see all alarms from 6:18pm.
Source
Enter the name of the system partition for which you wish to locate active alarms.
Refer to
to learn more about
the various system partitions on ZoneDAS.
Delete
Click the
Delete
button at the top right end to clear the log of all past alarms.
Refresh
Click the
Refresh
button to show all remaining past alarms.
Note: ZoneDAS can store up to 4096 past alarm entries. Once it reaches the limit, each
new entry will overwrite the oldest one.
The Alarm Settings Screen
The
Alarm Settings
screen allows the user to view the alarm definition table and modify
alarm severity classifications. It gives a listing of all alarms, ordered by category, and lets the
user configure each alarm’s various parameters. To access this screen, click
Fault > Alarm
Settings
.
Figure 34
Fault > Alarm Settings
The following table describes the labels on this screen.