Technical Reference for ZyXEL omni.net series
B-6
Extended S-Registers "ATSn=x"
All the Following Commands Require a 'AT' Prefix
S Com.
bit
dec
hex
Function and description
+Def./Ref.
S14=
bit
dec
hex
Bit mapped register
+002
0
0
0
omni.net auto-handshake mode on originate mode.
1
1
omni.net auto-handshake mode on answer mode.
S15=
bit
dec
hex
Bit mapped register
+130
0,1
0
0
Even
parity
2
2 (*)
No parity
2
0
0 (*)
1 stop bit
4,3
0
0 (*)
10-bit character length
*C0
7-5
0
0
Profile 0 as active settings after power on.
Z0
32
20
Profile 1 as active settings after power on.
Z1
64
40
Profile 2 as active settings after power on.
Z2
96
60
Profile 3 as active settings after power on.
Z3
128
80
(*)
Factory default as active settings after power on.
Z4
S16=
dec
Hex
Test status register.
+000
0
0
No test in progress.
9
9
Loopback test in progress.
&T9
10
A
Loopback with self-test in progress.
&T10
11
B
Loopback from B1, through switch, to B2.
&T11
S18=
dec
Force omni.net to fix DTE baud rate when idle.
+000
0 (*)
Disable fixed baud function
1-14,
32
1-E,
20
Enable baud rate to be fixed when answering.
Baud rate value settings same as S20, except for S18=32 at
230400 bps.
Summary of Contents for omni.net D
Page 4: ......
Page 16: ......
Page 20: ......
Page 21: ...Part I Introduction...
Page 22: ......
Page 46: ......
Page 47: ...Part II ISDN Function...
Page 48: ......
Page 61: ...Part III Voice Features...
Page 62: ......
Page 78: ......
Page 79: ...Part IV Data Function...
Page 80: ......
Page 88: ......
Page 107: ...Part V Fax Modem Function...
Page 108: ......
Page 119: ...Part VI Diagnostics Firmware Update...
Page 120: ......
Page 128: ......
Page 132: ......
Page 133: ...Part VII Appendices...
Page 134: ......
Page 152: ......
Page 180: ......