INTEGRATING THE SENSOR
To integrate the sensor, you will require a suitably sized LCD with a display area close to the
active area of the sensor, as shown in Figure 5 (the active area of the sensor can be found on
the corresponding Zytronic sensor drawing). Where possible, it is advisable to have the
active area of the sensor 2-3 mm oversized on all four edges in relation to the LCD display
area. This will allow for some misalignment during integration.
FIGURE 5
SUITABLE LCD TO MOUNT THE SENSOR TO
Foam gasket should be used around the perimeter of the LCD to provide an air gap between
the LCD face and the rear of the sensor, as shown in Figure 6. This air gap is necessary to
prevent excessive electrical noise from the LCD causing interference to the sensor.
Guidelines for the required thickness of the gasket can be seen in the table below and are
sufficient for most LCDs. Some LCDs with very high levels of noise may require greater
spacing which would need to be determined by testing.
SENSOR SIZE
GASKET THICKNESS
5 – 22˝
3mm
22 – 32˝
4mm
32 – 46˝
6mm
46 – 65˝
8mm
65 – 84˝
10mm
Summary of Contents for ZXY100
Page 1: ...PROJECTED CAPACITIVE ZXY100 TOUCH CONTROLLER SENSOR INTEGRATION MANUAL VERSION 1 1 ZXY100...
Page 4: ...1 INTRODUCTION...
Page 6: ...2 CONTROLLER VARIANTS...
Page 9: ...3 INTEGRATING THE SENSWOR...
Page 13: ...4 INTEGRATING THE CONTROLLER PCB...
Page 17: ...5 ATTACHING THE SENSOR FLEXIBLE CABLES...
Page 21: ...6 POWER AND DATA CONNECTIONS...
Page 26: ...7 USING A BEZEL...
Page 28: ...8 INTEGRATION CHECKS...
Page 30: ...9 CONTROLLER PCB DRAWINGS...
Page 37: ...10 SERIAL CABLE DRAWING...
Page 39: ...11 FURTHER INFORMATION...