To ensure normal operation and long service life of the device, please install it in an 
environment that meets the requirements described in the following subsection. 
Please keep a proper temperature and humidity in the equipment room. Too high/low 
humidity may lead to bad insulation, electricity leakage, mechanical property changes 
and corrosions. Too high temperature may accelerate aging of the insulation materials 
and can thus significantly shorten the service life of the device. For normal 
temperature and humidity of the device, please check the following table.

Summary of Contents for CooVox T200

Page 1: ...Quick Installation Guide F O R S M A L L B U S I N E S S IP PHONE SYSTEM CooVox T200 ...

Page 2: ... of an enterprise s office phone system T200 can support GSM modules WCDMA modules analog trunks SIP trunks or other VoIP system integration When used with the EX16S Expansion Box T200 supports mixed networking of analog phones and IP phones CooVox T200 can provide users with more convenience in application and management Thank you for using the ZYCOO IP PBX Please read the instructions carefully be...

Page 3: ...ONTENTS 1 Package Contents 2 Hardware Installation 2 Safety Precautions 5 Product Installation 10 Physical Connection 11 LED Definitions 12 Basic System Configuration 12 Web Login 13 Further Information ...

Page 4: ...ystem These are the items Included with your IP phone system purchase IP PBX T200 1PCS Power Adapter 1PCS Quick Installation Guide 1PCS Antenna only for GSM Warranty Card 1PCS Package Contents Two mounting brackets and fittings Network cable 1PCS ...

Page 5: ...e wrist strap and make sure that the wrist strap has a good skin contact and is well grounded The device works only under the correct power supply Please confirm that the power supply is consistent with the voltage marked by the device and it is suggested to use the included power supply Before the device is powered on please confirm that the power circuit will not be overloaded so as not to cause...

Page 6: ... the requirements described in the following subsection Please keep a proper temperature and humidity in the equipment room Too high low humidity may lead to bad insulation electricity leakage mechanical property changes and corrosions Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device For normal temperature and h...

Page 7: ...s Dust the device regularly and keep the indoor air clean Keep the device well grounded and ensure static electricity has been transferred 1 2 Electronic elements including capacitance and inductance on the device can be af fected by external interferences such as conducted emission by capacitance cou pling inductance coupling and impedance coupling To decrease the interferences please make sure t...

Page 8: ...le Check if the module is clean and intact Please ensure the power of IP PBX is cut off Please ensure the direction of the module is correct ZYCOO logo side up Push the module into the module slot through the guide rail Tighten the locking screws on both ends of the module 1 2 3 4 5 1 Do not touch any device on the module just to prevent the module from being damaged by static electricity 2 This o...

Page 9: ...acket Screw Check the grounding and stability of the rack Secure the supplied rack mounting brackets to each side of the device with supplied screws as illustrated in the following figure 1 2 Install IP PBX to the right place in the rack and then attach the brackets to the device 3 PWR SYS WAN LAN 1 2 3 4 1 2 3 4 CooVox T200 SLOT1 SLOT2 ...

Page 10: ...g of the rack which is the most important guarantee of avoiding ESD electricity leakage lightening and electromagnetic interference 2 Please mount devices in sequence from the bottom to top of the rack to avoid overloading 3 Please avoid any heavy thing placed on the device to avoid any unexpected accidents 4 Please ensure heat dissipation and air circulation 3 PWR SYS WAN LAN 1 2 3 4 1 2 3 4 CooV...

Page 11: ...s better for the protection of lightening Users can try to choose the most appropriate measure according to different situation If CooVox U100 IP PBX is installed in the computer room and the room has dedicated Grounding bar then the using of ground wire to connect the device with the Grounding bar is put to the first consideration as shown in the following figure 1 IP PBX Rear panel 2 Grounding T...

Page 12: ...hown in the following figure If you intend to connect the device to the ground via the PE Protecting Earth cable of AC power cord please make sure the PE Protecting Earth cable in the electrical outlet is well grounded in advance Notes 1 IP PBX Rear panel 2 AC Power Cord with PE cable 4 L N 1 2 SLOT2 SLOT1 USB Console LAN WAN Reset 100 240V AC ...

Page 13: ...10 Physical Connection Power Adapter PSTN Analog Phone Router ...

Page 14: ... on Power off System works System failure System doesn t boot Data transfer Disconnected Connected but no data transfer Data transfer Disconnected Connected but no data transfer Channel loading success Channel ringing Channel loading failure Channel loading success Channel ringing Channel loading failure Channel loading success Channel ringing Channel loading failure Green Blink Off Red Blink Off Red...

Page 15: ...1 xx if you are connected to WAN or 192 168 10 xx if you have connected to LAN 1 Enter the device s default IP address into the browser address bar to access the Web interface WAN port https 192 168 1 100 LAN port https 192 168 10 100 1 Open a web browser preferably Firefox Google Chrome or IE 11 or higher 1 Use the default login credential to access the CooVox T200 After logging in please change ...

Page 16: ...urations please refer to the user manual If you have other questions please contact the ZYCOO local dealers or distributors from where you purchased this product ZYCOO Co Ltd Addr No 1602 16th Floor Building No 599 Century City South Road High tech Zone Chengdu Sichuan Province China Tel 86 28 85337096 Website www zycoo com Support support zycoo com ...

Page 17: ...14 ...

Page 18: ...15 ...

Page 19: ...16 ...

Page 20: ...Co Ltd Leading IP Phone System Provider Address No 1602 16th Floor Building No 599 Century City South Road High tech Zone Chengdu Sichuan Province China Telephone 86 28 85337096 ext 813 815 Website www zycoo com ...

Reviews: