- 20 -
value.(the data is only for reference, can’t be used as medical data)
2.Put the chest band emitter on the chest, after 5 seconds, pulse rate show corresponding
pulse value.(the data is only for reference, can’t be used as medical data)-------this function is
optional.
(
6
)
Power saving mode:
This system has power saving function, at the standby state, if there is not any button pressing
instruction input in 4 minutes, system enter into power saving mode, shut down display
automatically,press any key can wake up system.
(
7
)
MP3
When the power is connected, connect MP3 or other audio devices, meter can play music.
1.When plug SD card and U disk, the volume is controlled on the meter, song choosing and
pausing is also controlled on the meter.
2.When only connect external MP3,volume is controlled on the audio devices, songs choosing
and pausing is also on the audio devices.
(
8
)
Metric Inch system change and incline adjustment
1.Press start button, take off safety key, then connect the safety key, can enter into metric and
Inch system switching, speed window display, press speed up or speed down ,choose metric
and Inch system (“SI” signify metric system, ”Eng” signify Inch system),after choosing, press
start button to confirm and drop out to standby state.
2.At the standby state, press speed+, speed-,, incline- buttons at the same time for 3
seconds, enter into incline automatically adjustment, after finishing adjustment, enter into
standby state.
(
9
)
Parameter setting
1.Control panel parameter setting
1)Press “speed+ “and “speed-“ at the same time ,then connect the power, or take off the safety
key then plug the safety key, wait till the calorie window and speed window show ”0”,release
“speed+” and” speed –“ buttons, enter into control panel parameter setting state;
2)At the parameter setting state, calorie window shows parameter no.0~9,speed window show
parameter value, using speed up or speed down button can amend the setting parameter,
pressing start button, confirm the setting parameter, and enter into next parameter setting.
when disconnect power or take off safety key, buzzer makes a beep sound, then plug safety
key, buzzer make a beep sound or press speed-up and speed-down at the same time, can
jump out of parameter setting.
3)Parameter
No.
Parameter definition
Unit
Programming range
0
Control panel configuration
1
Lowest speed
Km/h
0.3~3.0
2
Highest speed
Km/h
8.0~25.0
Summary of Contents for ZX-V8
Page 1: ...Owner s Manual Of The Motorized Treadmill...
Page 28: ...27...