background image

MAINTENANCE

1. YOUR ZURN AQUASPEC FAUCET HAS A HIGHLY POLISHED NICKEL CHROME PLATED FINISH.  CLEAN WITH SOAP  AND

WATER OR A MILD CLEANER WHICH IS SAFE FOR CHROME PLATING.  DO NOT USE ACIDS OR TOILET BOWL CLEANER
AS THEY WILL DAMAGE THE FINISH.

2. METERING CARTRIDGE (#3) REMOVAL AND REPLACEMENT

2.1. REMOVE COLORED INDEX BUTTON (#1C) FROM HANDLE (#1A)

2.2. LOOSEN SET SCREW (#1B) IN HANDLE WITH 3/32” ALLEN WRENCH

2.3. PULL UP ON HANDLE TO REMOVE FROM STEM (#2C) OF HANDLE NUT ASSEMBLY (#2)

2.4. REMOVE HANDLE NUT ASSEMBLY (#2) USING 1-1/8” HEX 6-POINT SOCKET

2.5. REMOVE METERING CARTRIDGE (#3) BY LIFTING OUT OF FAUCET BODY (#4). IT MAY BE NECESSARY TO OPEN

THE SUPPLY STOP SLIGHTLY TO ALLOW WATER PRESSURE TO PUSH THE METERING CARTRIDGE UPWARD.

2.6 INSPECT METERING CARTRIDGE (#3) FOR WORN PARTS, DAMAGED PARTS AND ANY CONTAMINATION THAT

MAY BE PREVENTING THE METERING CARTRIDGE FROM MOVING FREELY OR SEATING. OTHER THAN
CLEANING ANY TRAPPED DEBRIS, THERE ARE NO SERVICEABLE PARTS IN THE METERING CARTRIDGE.
CONTAMINATED OR DAMAGED METERING CARTRIDGE ASSEMBLIES SHOULD BE REPLACED.

2.7 REVERSE STEPS 2.1 THROUGH 2.5 FOR RE-ASSEMBLY. TIGHTEN CAP (#2F) WITH 1-1/8” HEX 6-POINT SOCKET

UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING.
HOLD DOWN HANDLE (#1A) WHILE TIGHTENING SET SCREW (#1B) TO ENSURE PROPER SEATING

3.

IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THE AERATOR PERIODICALLY TO REMOVE COLLECTED
SEDIMENT AND DEBRIS.

REPLACEMENT PARTS

HANDLE NUT ASSEMBLY

G60561

METERING CARTRIDGE ASSEMBLY

G67874

HANDLE ASSEMBLY

G60522

ADJUSTING THE CYCLE TIME ON ZURN METERING FAUCET

1.

METERING FAUCETS ARE FACTORY PRESET FOR A 5 TO 8 SEC. CYCLE AT 

35

0 kPa.

2.

ACTUATE FAUCET 3 TO 5 TIMES TO REMOVE ANY TRAPPED AIR IN THE SUPPLY LINE OR FAUCET

3.

REMOVE HANDLE (#1) PER INSTRUCTIONS IN MAINTENANCE SECTION 2.1 THROUGH 2.3 TO EXPOSE ADJUSTMENT
NUT (#2E)

4.

INCREASE CYCLE TIME BY TIGHTENING ADJUSTMENT NUT (#2E) 1/2 TURN CLOCKWISE. DECREASE CYCLE TIME BY
LOOSENING ADJUSTMENT NUT 1/2 TURN COUNTERCLOCKWISE. CHECK FOR DESIRED CYCLE TIME BY ACTUATING
FAUCET WITH HANDLE (#1) IN PLACE ON STEM (#2C)

PAGE 

2

 OF 4

ZURN.COM.AU

INST2018_Z-80300 Rev. 11/18

Summary of Contents for AQUASPEC Z80300-DZR Series

Page 1: ...CKING FOR LEAKS 5 INSTALL AERATORADAPTOR 5 AND AERATOR 6 INTO FAUCETAND HAND TIGHTEN 6 METERING CARTRIDGE IS FACTORY PRESET FOR A5 TO 8 SECOND CYCLE AT 350 kPa IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE FLOW SECTION PAGE 2 IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT FOREIGNMATTERANDDEBRISFROMCLOGGINGAND ORDAMAGINGINTERNALCOMPONENTSANDTHEREBYPREVENTIN...

Page 2: ...RING CARTRIDGE CONTAMINATED OR DAMAGED METERING CARTRIDGEASSEMBLIES SHOULD BE REPLACED 2 7 REVERSE STEPS 2 1 THROUGH 2 5 FOR RE ASSEMBLY TIGHTEN CAP 2F WITH 1 1 8 HEX 6 POINT SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING HOLD DOWN HANDLE 1A WHILE TIGHTENING SET SCREW 1B TO ENSURE PROPER SEATING 3 IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THEAERAT...

Page 3: ...65001 E Ring 1 2B 60464001 Spring Seat 1 2C 60451003 Stem 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2i 60458001 O Ring Retainer 1 3 G67874 Valve Sleeve Poppet Assembly 1 3A 58155020 O Ring 1 3B 81241001 Washer 1 4 61676010 DZR Body Single Flanged Wall Sink 1 5 93558001 Aerator Adaptor 1 6 60440001 0 5 GPM 1 9L Vandal Resis...

Page 4: ... GPM aerator Facuet may not shut off with aerator s 1 0 GPM Tighten handle nut using 1 1 8 hex 6 point socket to create seal and seat metering cartridge Do not over tighten Remove handle using 3 32 Allen wrench Rotate timing nut up CCW to shorten handle stroke and decrease cycle time Replace metering cartridge G67874 per Installation and Maintenance guide Supply stops not open Aerator contaminated...