 Item

Part Number

 Description

Qty.

1

G60522

Metering Handle Assembly

1

1A

60601003

Metering Handle

1

1B

62705001

Set Screw

1

1C

G60558

Metering Index Buttons H, C, T

1

60460001

Hot Index

1

60460002

Cold Index

1

60460003

Tempered Index

1

2

G60561

Handle Nut Assembly

1

2A

60465001

E-Ring

1

2B

60464001

Spring Seat

1

2C

60451003

Stem

1

2D

60447001

Spring

1

2E

60446001

Adjustment Nut

1

2F

60452001

Cap

1

2G

60456001

Stem Housing

1

2H

62499107

O-Ring

1

2i

60458001

O-Ring Retainer

1

3

G67874

Valve Sleeve/Poppet Assembly

1

3A

58155020

O-Ring

1

3B

81241001

Washer

1

4

61676010

DZR Body, Single Flanged Wall Sink

1

5

93558001

Aerator Adaptor

1

6

60440001

0.5 GPM [1.9L] Vandal-Resistant Pressure Compensating Spray Outlet

1

PAGE 

3

 OF 4

ZURN.COM.AU

INST2018_Z-80300 Rev. 11/18

Summary of Contents for AQUASPEC Z80300-DZR Series

Page 1: ...CKING FOR LEAKS 5 INSTALL AERATORADAPTOR 5 AND AERATOR 6 INTO FAUCETAND HAND TIGHTEN 6 METERING CARTRIDGE IS FACTORY PRESET FOR A5 TO 8 SECOND CYCLE AT 350 kPa IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE FLOW SECTION PAGE 2 IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT FOREIGNMATTERANDDEBRISFROMCLOGGINGAND ORDAMAGINGINTERNALCOMPONENTSANDTHEREBYPREVENTIN...

Page 2: ...RING CARTRIDGE CONTAMINATED OR DAMAGED METERING CARTRIDGEASSEMBLIES SHOULD BE REPLACED 2 7 REVERSE STEPS 2 1 THROUGH 2 5 FOR RE ASSEMBLY TIGHTEN CAP 2F WITH 1 1 8 HEX 6 POINT SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING HOLD DOWN HANDLE 1A WHILE TIGHTENING SET SCREW 1B TO ENSURE PROPER SEATING 3 IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THEAERAT...

Page 3: ...65001 E Ring 1 2B 60464001 Spring Seat 1 2C 60451003 Stem 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2i 60458001 O Ring Retainer 1 3 G67874 Valve Sleeve Poppet Assembly 1 3A 58155020 O Ring 1 3B 81241001 Washer 1 4 61676010 DZR Body Single Flanged Wall Sink 1 5 93558001 Aerator Adaptor 1 6 60440001 0 5 GPM 1 9L Vandal Resis...

Page 4: ... GPM aerator Facuet may not shut off with aerator s 1 0 GPM Tighten handle nut using 1 1 8 hex 6 point socket to create seal and seat metering cartridge Do not over tighten Remove handle using 3 32 Allen wrench Rotate timing nut up CCW to shorten handle stroke and decrease cycle time Replace metering cartridge G67874 per Installation and Maintenance guide Supply stops not open Aerator contaminated...

Reviews: