PROBLEM

CAUSE

SOLUTION

No water dispensing
from faucet.

Faucet is shutting
off to quickly

Faucet is running
too long.

Faucet will not
shut off.

Open supply stops.

Remove aerator to clean and/or replace.

Remove handle using 3/32” Allen wrench. Rotate timing
nut down (CW) to lengthen handle stroke and increase
cycle time.

Replace metering cartridge G67874 per Installation and
Maintenance guide.

Replace metering cartridge G67874 per Installation and
Maintenance guide.

Remove handle using 3/32” Allen wrench. Rotate timing
nut up (CCW) to shorten handle stroke and decrease
cycle time.

Install 1.0 GPM or 0.5 GPM aerartor. Cycle time may be
too long with aerator’s > 1.0 GPM

Replace metering cartridge G67874 per Installation and
Maintenance guide.

Install 1.0 GPM or 0.5 GPM aerator. Facuet may not shut
off with aerator’s > 1.0 GPM.

Tighten handle nut using 1-1/8” hex 6 point socket to
create seal and seat metering cartridge. Do not over
tighten.

Remove handle using 3/32” Allen wrench. Rotate timing
nut up (CCW) to shorten handle stroke and decrease
cycle time.

Replace metering cartridge G67874 per  Installation and
Maintenance guide.

Supply  stops not open.

Aerator contaminated.

Timing nut requires
adjustment.

Damaged Schrader valve
stem in center of
metering cartridge.

Metering cartridge is overly
contaminated or damaged.

Timing nut requires
adjustment.

Aerator is not installed or
incorrect aerator installed.

Metering cartridge is overly
contaminated or damaged.

Aerator is not installed
or incorrect aerator
installed.

Handle nut is not
adequately tightened

Timing nut requires
adjustment.

Metering cartridge is
overly contaminated or
damaged.

METERING FAUCET TROUBLE SHOOTING GUIDE

PAGE 

4

 OF 4

ZURN.COM.AU

INST2018_Z-80300 Rev. 11/18

Summary of Contents for AQUASPEC Z80300-DZR Series

Page 1: ...CKING FOR LEAKS 5 INSTALL AERATORADAPTOR 5 AND AERATOR 6 INTO FAUCETAND HAND TIGHTEN 6 METERING CARTRIDGE IS FACTORY PRESET FOR A5 TO 8 SECOND CYCLE AT 350 kPa IF ADJUSTMENT IS NECESSARY SEE ADJUSTING THE FLOW SECTION PAGE 2 IMPORTANTTHE WATER SUPPLY LINES MUST BE THOROUGHLY FLUSHED BEFORE INSTALLATION TO PREVENT FOREIGNMATTERANDDEBRISFROMCLOGGINGAND ORDAMAGINGINTERNALCOMPONENTSANDTHEREBYPREVENTIN...

Page 2: ...RING CARTRIDGE CONTAMINATED OR DAMAGED METERING CARTRIDGEASSEMBLIES SHOULD BE REPLACED 2 7 REVERSE STEPS 2 1 THROUGH 2 5 FOR RE ASSEMBLY TIGHTEN CAP 2F WITH 1 1 8 HEX 6 POINT SOCKET UNTIL NO WATER IS LEAKING FROM UNDER THE HANDLE NUT ASSEMBLY WHEN THE FAUCET IS RUNNING HOLD DOWN HANDLE 1A WHILE TIGHTENING SET SCREW 1B TO ENSURE PROPER SEATING 3 IT MAY BE NECESSARY TO REPLACE OR BACK FLUSH THEAERAT...

Page 3: ...65001 E Ring 1 2B 60464001 Spring Seat 1 2C 60451003 Stem 1 2D 60447001 Spring 1 2E 60446001 Adjustment Nut 1 2F 60452001 Cap 1 2G 60456001 Stem Housing 1 2H 62499107 O Ring 1 2i 60458001 O Ring Retainer 1 3 G67874 Valve Sleeve Poppet Assembly 1 3A 58155020 O Ring 1 3B 81241001 Washer 1 4 61676010 DZR Body Single Flanged Wall Sink 1 5 93558001 Aerator Adaptor 1 6 60440001 0 5 GPM 1 9L Vandal Resis...

Page 4: ... GPM aerator Facuet may not shut off with aerator s 1 0 GPM Tighten handle nut using 1 1 8 hex 6 point socket to create seal and seat metering cartridge Do not over tighten Remove handle using 3 32 Allen wrench Rotate timing nut up CCW to shorten handle stroke and decrease cycle time Replace metering cartridge G67874 per Installation and Maintenance guide Supply stops not open Aerator contaminated...

Reviews: