FV808 Rev. A 09/07/21
Page 7
Spout Installation Instructions (All Configurations)
Cover Plate Installation Instructions (Z6920 Only)
1. (For faucets with -CP4 or -CP8 suffix).
Pass sensor connector wire and shank through gasket. Align
gasket with faucet bottom and press firmly together. Pass sensor
connector and shank through cover plate and fasten to the faucet
with the provided screws.
2a. (Z6920): Install spout to sink using spout base gasket, plastic
mounting washer, star washer and mounting nut.
Note: Faucet location needs to be within 3 feet radius above
electrical outlet for ACA configurations.
NOTE
: Before installation, turn off water supplies to existing faucet and remove faucet if replacing an existing device.
Clean the faucet basin and clear away debris. Flush all supply lines before connecting the faucet. Failure to do so
may result in debris clogging the inlets and/or internal control and mixing valve of the faucet.
1. Carefully screw aerator into spout using included tool.
Take care to not pinch blue o-ring
3. Ensure that slot in plastic washer is facing forward.
Sensor cable should not pass through plastic mounting washer.
Z6920
Z6922
2b. (Z6922): Install spout to sink wall using spout base o-ring, plastic
mounting washer, mounting nut, and shank elbow.
Note: Faucet location needs to be within 3 feet radius above
electrical outlet for ACA configurations.