FV808 Rev. A 09/07/21
Page 13
Cable to
monitor
3. Install Monitor on wall surface within 2 feet radius of faucet
with dry wall anchors & screws or doubled sided VHB tape.
4. Loosen lid screw with supplied 3mm Allen wrench. Open lid
and install supplied lithium batteries. Close lid and secure by
pressing on the lid tab until it snaps into place. Then tighten
lid screw.
Lid screw
Lid tab
5. Connect monitor and electronics module assembly.
Do not connect cable to the spout at this step.
6. Open battery module using supplied 3mm Allen wrench and
install supplied alkaline batteries in the electronics module.
Then close and tighten battery module.
During initial installation, use the supplied alkaline batteries. During
subsequent battery changes, ONLY use alkaline batteries. Do not mix
alkaline and lithium batteries together.
During initial installation, use the supplied lithium batteries. During
subsequent battery changes, use either alkaline or lithium batteries;
however, do not mix alkaline and lithium batteries together.
During servicing or changing of batteries, wipe down monitor to ensure
water does not enter the housing when the lid is opened.
Monitor & Electronic Module Installation Instructions (-W2)
B
A
2. Connect sensor inline connector to electronics module and to
the hydrogenerator.
C
1. Connect hydrogenerator(A) downstream of electronics
module(B); connect the electronics module(B) downstream of
filter(C).
Do not connect the electronic module to spout.