B.1 Selecting a frequency range
1. Press <ON> of SiteMaster to turn on the meter.
2. Press <FREQ> on the main menu.
3. Press <F1> on the [Frequency] menu.
4. Input the frequency for [Lower], such as “825MHz”, and then press <ENTER>
for confirmation.
5. Press <F2> on the [Frequency] menu.
6. Input the frequency for [Higher], such as “880MHz”, and then press <ENTER>
for confirmation.
7. When confirmed, press <MAIN> to return to the main menu.
B.2 Checking SiteMaster
SiteMaster shall be checked in the case of frequency, environment and feeder
parameters changes. Follow these steps to check:
1. Make sure that a correct frequency range is input in SiteMaster, then begin the
check.
2. Press <STARTCAL> to begin the check.
3. Press <Measuring OPEN>, <MeasuringSHORT>, and <Measuring Load> one
by one as prompted to complete the check.
4. Include the extension cable came with the meter to the check for measurement
accuracy.