16
Quick change system for SPRINT Series
Using a suitable spanner set the
absorving energy of the system with
which the cap attachment has to be
pushed in the guides on the centring
devices.
Fig. 30: Centring device, force setting
Check the setting by moving back and forth the cap attachment. Change and
check the settings of the absorving power until you find the appropriate setting.
Centring device
Impact
Setting tighter
higher effort
Setting looser
smaller effort
The setting is right if the cap attachment slides into both clevises evenly under
slight pressure.
A new adjustment of the clamping screws on the horizontal clamping
fixtures is not necessary.
Fig. 31: Pantograph drive, cabinet slot
Please pay attention when inserting the centring devices in the clevis, that the
lower clamping devices of the cap attachment are opened wide enough and that
the threads of the lower clamping devices sit in the two slots of the cabinet on the
pantograph drive for lateral movement.
If you can not position the cap attachment accordingly, the pantograph can move
laterally and brought into position by means of the pantograph control.