13
Quick change system for SPRINT Series
Set over the lower nuts of the two
clamping screws the contact pressure
of the two horizontal clamping fixture.
The adjustment of the thrust screw is
countered with the upper nuts of the
two clamping screws.
Fig. 23:
Clamping screws, adjustment
Check the setting of the comprehensive force by repeatedly opening and closing
the horizontal clamping fixture.
Close the horizontal clamping fixture completely.
The horizontal clamping fixtures are correctly adjusted when they can be
completely closed with a
clear click-sound
and
not much effort
.
Contact pressure
Impact
to small
no click sound
correct
clear click sound
to high
effort when closing the clamp too
high, horizontal clamping fixture
is very difficult to close.
The basic setting of the quick change system is herewith concluded.
The cylinder arm frame holder can be used now with the quick change system.
Replace the cover of the pantograph drive for lateral movement. 2 screws with
plastic sheaves on the top and the 3 screws with plastic sheaves at the back of the
cover. See
.
Fig. 24: Tubular frame mounted