ISO 80079-37:2016-07 Explosive atmospheres - Part 37: Non-electrical equipment for
explosive atmospheres - Non-electrical type of protection constructional safety “c,” control
of ignition sources “b,” liquid immersion “k.”
The Zortrax Apoller has been marked:
II 1/- G Ex h IIA T2 Ga/-
The restrictions of the device’s use in accordance with symbols present in the above mar-
king and on the nameplate of the device:
Name
ATEX
Marking
Explanation
Explosion protection
mark
Symbol of equipment for use in explosive at-
mospheres.
Note: Read the equipment category explana-
tion.
Equipment group
II
Equipment intended for use in explosive at-
mospheres other than underground mining
works.
Equipment category
1/- G
Equipment is not intended for use in potential-
ly explosive atmospheres.
Due to the nature of the technological pro-
cess, the device has been designed and pro-
duced in such a way to prevent the risk of
explosion caused by components in contact
with the process medium or vapors of flam-
mable liquids used for operation.
Type of protection
Ex h
Constructional safety according to normative
requirements.
Group
IIA
Classification by the type of medium used for
operation and by the presence of flammable
gases: explosion subgroup IIA (propane).
Summary of Contents for Apoller