Error Messages
Whenever there is a technical issue caused by a hardware failure, negligence or inappropriate
use of the Zortrax Apoller device, the firmware immediately displays an error message on the
screen. The following list explains all error messages and provides potential causes and sug-
gested solutions.
Error message
Potential cause
Suggested solution
#002 STIRRER_RPM_ERROR
Rotational speed of the stirrer
is not sufficient. The stirrer
has worn off or the sensor of
the stirrer speed has failed.
Contact Zortrax Support
Center through the support
form:
https://support.zortrax.
com/support-form/
.
#003 STIRRER_FUSE_BURN
Stirrer fuse has got damaged.
Replace the stirrer fuse.
If the problem reoccurs,
contact Zortrax Support
Center through the support
form:
https://support.zortrax.
com/support-form/
.
#005 PRESSURE_DROP_ERROR
Pressure in the chamber is
too high. The gasket might
be dirty, filler cap might not
be tightened, or the vacuum
system has failed.
Clean the door gasket and
make sure the filler cap is
properly tightened. If the pro-
blem reoccurs, contact Zortrax
Support Center through the
support form:
https://support.
zortrax.com/support-form/
.
#007 PRESSURE_LEVEL_ERROR
Pressure during the smoothing
process has reached too high
value. Either pressure measure-
ment or solvent supply system
has failed.
Contact Zortrax Support Cen-
ter through the support form:
https://support.zortrax.com/
support-form/
.
#009 UPPER_FAN_FAIL
Speed of the upper fan is not
sufficient.
Contact Zortrax Support Cen-
ter through the support form:
https://support.zortrax.com/
support-form/
.
#011 SIDE_FAN_FAIL
Speed of the side fan is not
sufficient.
Contact Zortrax Support Cen-
ter through the support form:
https://support.zortrax.com/
support-form/
.
Summary of Contents for Apoller