Probl
Probl em
em
Cause
Cause
Remedy
Remedy
When the relay
When the relay
of motor is
of motor is
electrified, it
electrified, it
can not output
can not output
signals.
signals.
The
The relay
relay or
or control
control panel
panel fails.
fails.
Replace
Replace control
control panel.
panel.
The motor can
The motor can
not rotate.
not rotate.
The main motor can not rotate after
The main motor can not rotate after
it is electrified or the rotational speed
it is electrified or the rotational speed
is too low.
is too low.
Check motor connection. Pull
Check motor connection. Pull
out plug to check motor, if it can
out plug to check motor, if it can
not rotate or the rotational speed
not rotate or the rotational speed
is low, replace motor. Otherwise
is low, replace motor. Otherwise
replace the control panel.
replace the control panel.
The water
The water
temperature
temperature
sensor is
sensor is
short-circuited.
short-circuited.
There is water in sensor or the
There is water in sensor or the
circuit board is wet.
circuit board is wet.
Replace sensor or control box.
Replace sensor or control box.
The water
The water
temperature
temperature
sensor breaks.
sensor breaks.
The sensor line breaks off or the
The sensor line breaks off or the
circuit board fails.
circuit board fails.
Replace sensor or control box.
Replace sensor or control box.
The flame
The flame
detector can
detector can
not be ignited.
not be ignited.
The flame detector does not output
The flame detector does not output
flame signal.
flame signal.
Check connection of flame
Check connection of flame
detector, replace the detector or
detector, replace the detector or
control panel.
control panel.
Extinguish
Extinguish
flame during
flame during
burning.
burning.
Extinguish flame during burning and
Extinguish flame during burning and
can not burn again.
can not burn again.
If the oil tank is short of oil, add
If the oil tank is short of oil, add
oil; If the oil pipe leaks, tighten
oil; If the oil pipe leaks, tighten
or replace it; replace
or replace it; replace
short-circuited flame detector
short-circuited flame detector
and control box.
and control box.
Strong
Strong
interference
interference
Other interferences.
Other interferences.
Close other interference source,
Close other interference source,
replace control panel.
replace control panel.
The ignition
The ignition
plug breaks.
plug breaks.
The ignition plug burn out or the line
The ignition plug burn out or the line
looses.
looses.
Fasten connection, replace
Fasten connection, replace
ignition plug.
ignition plug.
The ignition
The ignition
plug is
plug is
short-circuited.
short-circuited.
It
It is
is short-circuited.
short-circuited.
Check
Check it.
it.
The ignition
The ignition
plug relay has
plug relay has
no output
no output
signal.
signal.
The
The relay
relay or
or the
the control
control panel
panel fails.
fails.
Replace
Replace control
control panel.
panel.
Summary of Contents for QY30V
Page 8: ......
Page 10: ......
Page 36: ......
Page 56: ......
Page 94: ......
Page 144: ...04 49 04 49 Operation crane superstructure Operation crane superstructure Fig 04 40 Fig 04 40...
Page 146: ......
Page 156: ...05 9 05 9...
Page 158: ......
Page 170: ......
Page 202: ......
Page 242: ...08 39 08 39 M60 M60 66 66 1008 1008 1418 1418...
Page 244: ......
Page 272: ...09 27 09 27...
Page 274: ......