MEYERTECH LIMITED
ISSUE 09
1.
INSTALLATION
1.1 EQUIPMENT
The ZVK-007 should be carefully unpacked and the contents checked against the list below.
ZVK-007 KEYBOARD (19 Inch By 4U Panel Mounted)
MAINS CUBE PSU.
ZoneVu NETWORK NODE BOX
1.2 CONNECTING THE ZVK-007 TO THE ZONEVU NETWORK
STEP 1
Wire the Mains Cube PSU to the Network Node box observing the
polarity. Set the PSU to give +12V output.
STEP 2
Wire the Network Node box to the ZoneVu Network observing the
polarity of the connections and ensuring that the screen of the Network
cable is connected to the PSU 0V connection.
STEP 3
Plug the Mains Cube into a convenient power socket.
STEP 4
Plug the ZVK-007 into the FCC connector on the Network Node box.
1.3 KEYBOARD ADDRESS
Each keyboard connected to the ZoneVu network requires a unique
Module Access Code
(MAC) to
function correctly. Set the MAC by following the procedure in Section 6.5.3.
NOTE ! The MIC (Module Identification Code) is not used by the ZVK-007 and can be ignored.
1.4 SERIAL COMMUNICATIONS
The ZVK-007 can operates on a RS422 Topology with the following parameters -
BAUD RATE
-
9600 / 19200 / 38400
STOP BITS
-
1
DATA BITS
-
8
FRAME
-
10 BIT
PARITY
- NONE
FLOW
- NONE
Page 5
http://www.meyertech.co.uk
MAN-007