8.  Rule 35 (e) 
 

…four blasts in succession, namely one prolonged followed by three short blasts: 

 

- a vessel towed or if more than one vessel is towed the last vessel of the tow 

 
 
9.  Rule 35 (g) 
 

…rapid ringing of the bell for 5 seconds at intervals of 1 minute: 

-  a vessel at anchor 

…supplemented by rapid sounding of the gong for 5 seconds at intervals of 1 minute 
- a vessel at anchor which is more than 100 m in length 

 
 
9.1. A vessel at anchor may in addition sound three blasts in succession, namely one short, one 
 

 prolonged and one short blast. 

 
 
10. Rule 37 Annex IV-SOS 
 

 emergency signal SOS repeated continuously. 

 
 
11. Signal MOB (man over board) 
 

 three prolonged blasts in succession repeated continuously 

 
 
Additional acoustic and optic signals can be released manually by at will push-buttons. 
 
 
 
Operation of the Signal Automaton 10+SGA 
 
After  installation  and  electric  connection  on  board  of  the  vessel,  the  automaton  is  in  stand-by 
mode  unless  there  is  an  interruption  of  the  power  supply.  The  stand-by  mode  is  indicated  by 
illuminated  symbols  of  all  signal  keys,  except  for  the  red  indicating  LEDs  which  will  be 
illuminated only when a program has been selected. 
 
 
Attention! 
 
Before selecting a new program, the key “I/O” must be hit to delete the preceeding program. All 
at  will  keys  for  manual  sound  signal  release  have  priority.  Hitting  any  of  the  at  will  keys  for 
manual sound signal release will cut off the running automatic program. 

07.12 Pi 

ZÖLLNER - KIEL

 

01808851.05-4e 

Subject to alteration! 

Summary of Contents for Signal Automaton 10+SGA

Page 1: ...g system separate push buttonkeys signal intervals adjustable dimmer for key illumination latest technical standard made in Germany functional membrane keyboard self explanatory symbols installation o...

Page 2: ...omatic on off Regel rule 35a b c e g Automatic on off Regel rule 35g bell gong 144 Warnsignal attention Steuerbord starboard Backbord port R ckw rts astern Horn whistle Licht general alarm abandon shi...

Page 3: ...or audio Gener al Alar m Exter n Stop Gen Al PA System 1 Bell Gong 11 12 Abandom Ship GA signal output f or lamp ZB110 ZG110 01506539 4 MH 05 13 or muting S R D Manual Alar m Bell Gong 1 muting Whistl...

Page 4: ...1 Bell Gong 11 12 1 muting SRD ZB110 ZG110 01506540 4 MH 05 13 or muting S R D 1phase...

Page 5: ...aneuver is finished the off key O must be pushed for switching off 4 Rule 34 d When vessels in sight of one another are approaching each other and from any cause either vessel fails to understand the...

Page 6: ...signal SOS repeated continuously 11 Signal MOB man over board three prolonged blasts in succession repeated continuously Additional acoustic and optic signals can be released manually by at will push...

Page 7: ...ivated by external push button 3rd key switching on off of automatic bell and gong signals in restricted visibility Rule 35 g Activation of this function is indicated by a red LED next to the key Sign...

Page 8: ...l Trouble shooting and fault deletion Manual signal release is not possible and key illumination fails 1 Check correct connection of terminals 2 3 to power supply indicated on the name plate 2 Check f...

Page 9: ...age 90 264 V AC 24 V DC 50 60 Hz 2 Horizontal or vertical installation is possible 3 For mechanical installation a cutout of 139 x 139 mm in the bridge console is necessary Plug in depth is 120 mm 3 1...

Page 10: ...ng off 4 Rule 34 d When vessels in sight of one another are approaching each other and from any cause either vessel fails to understand the intentions or actions of the other or is in doubt whether su...

Page 11: ...repeated continuously 11 Signal MOB man over board three prolonged blasts in succession repeated continuously Additional acoustic and optic signals can be released manually by at will push buttons Ope...

Page 12: ...g signals in restricted visibility Rule 35 g Activation of this function is indicated by a red LED next to the key Signal keys in 2nd row from left to right 1st key all manual sound signals 2nd key sw...

Page 13: ...ing and fault deletion Manual signal release is not possible and key illumination fails 1 Check correct connection of terminals 2 3 to power supply indicated on the name plate 2 Check fuses F1 and F2...

Page 14: ...DC 50 60 Hz 2 Horizontal or vertical installation is possible 3 For mechanical installation a cutout of 139 x 139 mm in the bridge console is necessary Plug in depth is 120 mm 3 1 The automaton is in...

Page 15: ...V 17100095 4d e 03 13 MH 10 SGA Art Nr 0171610...

Reviews: