PUMP ELECTRICAL CONNECTIONS

CONTINUED

2.  Insert an electrical wire strain relief into the opening in the side of the pressure switch closest to the motor (Fig. 2).
3.  Thread the cable from the pump motor through the strain relief into the pressure switch cavity and tighten both screws on the strain relief. Do not 

crush wire (Fig. 3).

4.  Connect the two motor wires of the motor cable to the two inside terminals on the pressure switch (Fig. 4).
5.  Connect the green ground wire from the motor cable to one of the green ground screws at the bottom of the pressure switch (Fig. 5).

IL1372

2

IL1373

Wire from 

motor

3

IL1374

Wire from 

motor

4

IL1375

Wire from 

motor

Ground Screws

5

IL1376

Wire from 

motor

6

IL1377 

Wire from 

motor

Wire from 

power

supply

7

IL1378

Wire from 

motor

Wire from 

power

supply

8

IL1379

Wire from 

motor

Wire from 

power

supply

Ground Screws

9

6.  Insert an electrical wire strain relief into the opening in the opposite side of the pressure switch (Fig. 6).
7.  Thread the cable from the power supply through the strain relief and tighten both screws on the strain relief. Do not crush wire (Fig. 7).
8.  Connect the two wires from the power supply to the two outside terminals on the pressure switch (Fig. 8).
9.  Connect the green ground wire from the power supply to the remaining green ground screw in the pressure switch and re-attach the 

pressure switch cover (Fig. 9).

10

11a

11b

11c

To change from 115V to 230V
10.  The motor of this pump is dual voltage and can run on either 115V or 230V. In general, 230V is more economical to run, and requires a smaller 

wire size. The 1/2 HP model is factory preset to run at 115V (Fig. 10).  
NOTE: 1 HP models are factory preset to operate at 230V. 

11.  For 230V service, change the following wires on the terminal board:

a. 

Using a pair of needle nose pliers, pull the gray wire with the female flag connector from the “A” terminal spade post. Place it to the right 

on the “B” terminal space post (Fig. 11a).

b. 

Pull the red wire with the female flag connector from the “L2” terminal. Place it to the left on the “B” terminal space post (Fig. 11b).

c.  Reinstall the rear motor cover (Fig. 11c).

 NOTE: To change 1 HP models to 115V, simply reverse instructions above. 

IL1372

IL1373

IL1374

IL1375

IL1376

IL1377

IL1378

IL1379

IL1354A

IL1355A

IL1356A

IL1270

Summary of Contents for NE462

Page 1: ...be followed THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP MAINTAIN ALL SAFETY DECALS Table of Contents Safety Instructions 1 Limited Warranty 2 Preinstalla...

Page 2: ...IAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESS...

Page 3: ...by wiring the unit to a ground metal clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means 6 Hazardous Pressure Install pressur...

Page 4: ...and in accordance with local and state codes PIPING 1 Old or badly scaled pipe should not be used because dislodged flakes of scale can cause stoppage of the ejector nozzle and malfunction the entire...

Page 5: ...tion 1 Ball Valve plastic 2 3 4 in x 1 4 in bushing steel 3 Pressure Gauge 4 Pump stand for tank 5 Well adapter for single pipe packer installations straight and right angle shown NOTE For a successfu...

Page 6: ...e Pipe System Where water level is greater than 25 feet and inside diameter of well is 4 or larger 1 Attach the foot valve to the ejector using a galvanized steel or plastic nipple Add enough 1 in pre...

Page 7: ...d check for leaks by pouring water into the suction pipe 4 Attach well adapter to suction pipe lower over casing top and tighten adapter flange 5 If no leaks are found proceed to WELL TO PUMP CONNECTI...

Page 8: ...ll with additional pipe and fittings as needed Fig 5 Shallow Well Application Only CAUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts Follow all proper gluing procedure...

Page 9: ...7 5 Glue Deep Well Application Only 1 To begin the connection to the pressure tank loosely assemble flow control body to pump head Using Teflon tape position the discharge outlet of the control body f...

Page 10: ...on this page or step by step instructions on page 11 Your pump motor has a built in thermal overload that protects the motor against burnout from overload of low voltage high voltage and other causes...

Page 11: ...y through the strain relief and tighten both screws on the strain relief Do not crush wire Fig 7 8 Connect the two wires from the power supply to the two outside terminals on the pressure switch Fig 8...

Page 12: ...ming voltage matches the pump wiring voltage See wiring guide in the instructions NOTE Watch for leaks or a milky color in the discharged water which indicates an air leak Make sure foot valve and or...

Page 13: ...the pump is being used for shallow well applications the flow control screw should be set in the full open position IMPORTANT If the pump fails to prime within five minutes Turn power off at the break...

Page 14: ...of liquid soap to the inside diameter of the rubber drive ring 7 Replace the impeller and diffuser removed in Steps 2 3 8 Reassemble the pump body to the motor and mounting bracket MOTOR REPLACEMENT...

Page 15: ...ng Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Control Assembly Control Body Flow Control Screw Pump Body Plug 1 4 NPT Pressure Switch Cap Screws 3 8 x 3 4 Base Lead Wire 1...

Page 16: ...pany 2 Reprime if necessary 3 Rearrange piping to eliminate air lock 4 Replace undersized piping or install pump with higher capacity 5 Tighten all fittings and replace control if necessary 6 Make sur...

Reviews: