background image

6

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

INSTALLING PIPING IN WELL 

Shallow Well Application 

Where suction lift is less than 25'
1.   On single pipe installations (Fig. 1) attach foot valve to the end of the suction pipe and set in the well, making certain the valve is below the 

water level. The foot valve should at least five (5) feet from the bottom of the well to prevent sand from being drawn into the system.

2.   When connecting a drive point (Fig. 2) a check valve must be used in the 

suction line in place of a foot valve. For easy priming connect the check valve 

as close to the well as possible.

3.   All piping from the well to the pump should slope slightly upward with no 

sagging. Support suction pipe between water source and pump. Unions 

in the suction line near the pump and well will aid in servicing.  Be sure to 

leave enough room so that wrenches can be used easily.

Water Level

25 ft.

Max

Suction 

Lift

3/4 or 1 in. 

Discharge Pipe

1-1/4 in.

Suction

Pipe

Discharge 

to Home 

Pipe 

Support

Foot Valve

1

IL1188

3/4 in. 

Discharge Pipe

1-1/4 in.

Suction

Pipe

Discharge 

to Home 

2

Recommended Suction Pipe Sizes

For Shallow Well Pump

Length Of Offset From Well In Feet

Motor

HP Size

Vertical 

Piping

0-20’

20-100’

1/2

1”

1”

1-1/4”

1

1-1/4”

1-1/4”

1-1/4”

Deep Well (Double Pipe System)

Where water level is greater than 25 feet and inside diameter of well is 4" or larger

1.   Attach the foot valve to the ejector using a galvanized steel or plastic nipple. Add enough 

1 in. pressure pipe and 1-1/4 in suction pipe to submerge ejector 10 to 15’ below pumping 

water level, making certain foot valve is at least five (5) feet from bottom of well.  If 

pressure pipe and suction pipe of the same diameter are used, be sure to identify them 

clearly so that they will be connected to the proper tappings of the pump.

       If a known well leak exists, replace nipple with 21 feet of 1” tail pipe between the ejector 

and the foot valve.  This will provide a continuous source of water for the pumping system. 

2.   Check pipe and foot valve for leaks by filling pipes 

with water.  A continuous loss of water 

indicates a leak in the piping, foot valve or unions, and must be corrected.

3.   If no leaks are found, proceed to WELL TO PUMP CONNECTION (SUCTION PIPE). For 

long offset distances, see chart below for proper pipe size.

4.    All piping from the well to the pump should slope slightly upward with no sagging. Support 

suction pipe between water source and pump. Unions in the suction line near the pump and 
well will aid in servicing. Be sure to leave enough room so that wrenches can be used easily.

IL1184

Water 

Level

Suction 

Lift

3/4 in. 

Discharge 

Pipe

1-1/4 in.

Suction

Pipe

Discharge 

to Home 

Pipe 

Support

Foot Valve

1 in.

Pressure

Pipe

4 in. ID Well

Ejector

IL1187

Summary of Contents for NE462

Page 1: ...be followed THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP MAINTAIN ALL SAFETY DECALS Table of Contents Safety Instructions 1 Limited Warranty 2 Preinstalla...

Page 2: ...IAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESS...

Page 3: ...by wiring the unit to a ground metal clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means 6 Hazardous Pressure Install pressur...

Page 4: ...and in accordance with local and state codes PIPING 1 Old or badly scaled pipe should not be used because dislodged flakes of scale can cause stoppage of the ejector nozzle and malfunction the entire...

Page 5: ...tion 1 Ball Valve plastic 2 3 4 in x 1 4 in bushing steel 3 Pressure Gauge 4 Pump stand for tank 5 Well adapter for single pipe packer installations straight and right angle shown NOTE For a successfu...

Page 6: ...e Pipe System Where water level is greater than 25 feet and inside diameter of well is 4 or larger 1 Attach the foot valve to the ejector using a galvanized steel or plastic nipple Add enough 1 in pre...

Page 7: ...d check for leaks by pouring water into the suction pipe 4 Attach well adapter to suction pipe lower over casing top and tighten adapter flange 5 If no leaks are found proceed to WELL TO PUMP CONNECTI...

Page 8: ...ll with additional pipe and fittings as needed Fig 5 Shallow Well Application Only CAUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts Follow all proper gluing procedure...

Page 9: ...7 5 Glue Deep Well Application Only 1 To begin the connection to the pressure tank loosely assemble flow control body to pump head Using Teflon tape position the discharge outlet of the control body f...

Page 10: ...on this page or step by step instructions on page 11 Your pump motor has a built in thermal overload that protects the motor against burnout from overload of low voltage high voltage and other causes...

Page 11: ...y through the strain relief and tighten both screws on the strain relief Do not crush wire Fig 7 8 Connect the two wires from the power supply to the two outside terminals on the pressure switch Fig 8...

Page 12: ...ming voltage matches the pump wiring voltage See wiring guide in the instructions NOTE Watch for leaks or a milky color in the discharged water which indicates an air leak Make sure foot valve and or...

Page 13: ...the pump is being used for shallow well applications the flow control screw should be set in the full open position IMPORTANT If the pump fails to prime within five minutes Turn power off at the break...

Page 14: ...of liquid soap to the inside diameter of the rubber drive ring 7 Replace the impeller and diffuser removed in Steps 2 3 8 Reassemble the pump body to the motor and mounting bracket MOTOR REPLACEMENT...

Page 15: ...ng Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Control Assembly Control Body Flow Control Screw Pump Body Plug 1 4 NPT Pressure Switch Cap Screws 3 8 x 3 4 Base Lead Wire 1...

Page 16: ...pany 2 Reprime if necessary 3 Rearrange piping to eliminate air lock 4 Replace undersized piping or install pump with higher capacity 5 Tighten all fittings and replace control if necessary 6 Make sur...

Reviews: