background image

5

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

Tools required

PREPARATION

Pipe wrenches (2)

Wire strippers

Needle-nose pliers

Phillips screwdriver

Adjustable wrench

Pipe tape

Pipe dope

Wire cutters

Parts You May Need For Assembly  

not included (Fig. 1)

Item Description

1

1-1/4 In. union

2

1-14 in. adapter

3

1-1/4 in. elbow

4

3/4 in. union

5

1 in. adapter

6

1 in. x 3/4 in. reducer bushing

7

3/4 in. adapter

8

1 in. elbow

9

1-1/4 in. check valve

10

3/4 in. tee (plastic)

11

3/4 in. tee (steel)

12

3/4 in. x 3 in. nipple (steel)

13

3/4 in. plug (steel)

14

Foot Valve

Electric cord strain relief

Optional Parts For Assembly  

not included (Fig. 2)

Item Description

1

Ball Valve (plastic)

2

3/4 in. x 1/4 in. bushing (steel)

3

Pressure Gauge

4

Pump stand for tank

5

Well adapter for single pipe packer installations 

(straight and right angle shown)

NOTE: 

For a successful installation, take time to study your application for the correct pipe size and appropriate fittings. The illustrations in these 

instructions will assist you with required and optional fittings. Sch. 40 PVC plastic pipe and fittings were used in these instructions.

Before beginning installation of product, make sure all parts are present. If any part is missing or damaged, do not attempt to assemble the 

product. Contact customer service for replacement parts.

Estimated Installation Time: 2 hours.

IL1385

lıı

ılı

ııı

lıı

ılı

ııı

lııı

lııı

ılıı

ılıı

ıılııı

lııı

ılıı

ılıı

ıı

200

180

160

140

120

100

80

60

40

20

1

2

3

4

2

5

1

IL1382

4

1

2

5

7

9

14

11

3

6

8

10

13

12

IL1382

IL1385

Summary of Contents for NE462

Page 1: ...be followed THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP MAINTAIN ALL SAFETY DECALS Table of Contents Safety Instructions 1 Limited Warranty 2 Preinstalla...

Page 2: ...IAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESS...

Page 3: ...by wiring the unit to a ground metal clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means 6 Hazardous Pressure Install pressur...

Page 4: ...and in accordance with local and state codes PIPING 1 Old or badly scaled pipe should not be used because dislodged flakes of scale can cause stoppage of the ejector nozzle and malfunction the entire...

Page 5: ...tion 1 Ball Valve plastic 2 3 4 in x 1 4 in bushing steel 3 Pressure Gauge 4 Pump stand for tank 5 Well adapter for single pipe packer installations straight and right angle shown NOTE For a successfu...

Page 6: ...e Pipe System Where water level is greater than 25 feet and inside diameter of well is 4 or larger 1 Attach the foot valve to the ejector using a galvanized steel or plastic nipple Add enough 1 in pre...

Page 7: ...d check for leaks by pouring water into the suction pipe 4 Attach well adapter to suction pipe lower over casing top and tighten adapter flange 5 If no leaks are found proceed to WELL TO PUMP CONNECTI...

Page 8: ...ll with additional pipe and fittings as needed Fig 5 Shallow Well Application Only CAUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts Follow all proper gluing procedure...

Page 9: ...7 5 Glue Deep Well Application Only 1 To begin the connection to the pressure tank loosely assemble flow control body to pump head Using Teflon tape position the discharge outlet of the control body f...

Page 10: ...on this page or step by step instructions on page 11 Your pump motor has a built in thermal overload that protects the motor against burnout from overload of low voltage high voltage and other causes...

Page 11: ...y through the strain relief and tighten both screws on the strain relief Do not crush wire Fig 7 8 Connect the two wires from the power supply to the two outside terminals on the pressure switch Fig 8...

Page 12: ...ming voltage matches the pump wiring voltage See wiring guide in the instructions NOTE Watch for leaks or a milky color in the discharged water which indicates an air leak Make sure foot valve and or...

Page 13: ...the pump is being used for shallow well applications the flow control screw should be set in the full open position IMPORTANT If the pump fails to prime within five minutes Turn power off at the break...

Page 14: ...of liquid soap to the inside diameter of the rubber drive ring 7 Replace the impeller and diffuser removed in Steps 2 3 8 Reassemble the pump body to the motor and mounting bracket MOTOR REPLACEMENT...

Page 15: ...ng Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Control Assembly Control Body Flow Control Screw Pump Body Plug 1 4 NPT Pressure Switch Cap Screws 3 8 x 3 4 Base Lead Wire 1...

Page 16: ...pany 2 Reprime if necessary 3 Rearrange piping to eliminate air lock 4 Replace undersized piping or install pump with higher capacity 5 Tighten all fittings and replace control if necessary 6 Make sur...

Reviews: