Illustrated Parts Breakdown

Drain Pump 105 Pic tured

Drain Pump 104 Pic tured

2

7

4

5

8

6

1

9

10

11

3

12

CHECK VALVE

(PURCHASED
SEPARATELY)

13

SK2008B

10

11

9

2

5

12

3

7

4

1

8

6

13

SK2008A

 MODELS

105, 110, 115, 120

131

104

ITEM

DESCRIPTION

QTY

08/00

thru

Current

08/00

thru

Current

08/00

thru

Current

1 Drain 

Pump

1

105-0001

131-0001

104-0005

110-0001

N/A

N/A

115-0001

N/A

N/A

120-0001

N/A

N/A

2

Md. "M72" (See FM1722)

1

N/A

N/A

72-0001

 

Md. “M53” (See FM0472)

007917

N/A

N/A

“M55” (See FM0537)

    

007918

N/A

N/A

“M57” (See FM0431)

    

007919

N/A

N/A

“M59” (See FM0432)

    

007920

N/A

N/A

“M98” (See FM1032)

    

N/A

007921

N/A

3 Basin 

Tank

1

013017

013017

013017

4

Discharge Tube

1

013732

014759

013732

Basin - Lid

1

013018

013018

013018

6

Hard ware  Pack

1

013731

013731

013731

7 Basin 

Seal

1

N/A*

N/A*

N/A*

8 Unicheck

1

30-0181

30-0181

30-0181

¼ - 20X1" lg. RHM Screw S.S.  

8

N/A*

N/A*

N/A*

10 

¼ - Flat Washer S.S.      

16

N/A*

N/A*

N/A*

11 

¼ - 20 Hex. Hd. Nut - S.S.

8

N/A*

N/A*

N/A*

12

Pipe Cap w/o-ring 

1

N/A*

N/A*

N/A*

13

O-Ring

1

N/A*

N/A*

N/A*

 *When ordering this item order the hardware pack item #6.

Summary of Contents for 104

Page 1: ...OURCE BEFORE HANDLING Single phase pumps are supplied with a 3 prong grounded plug to help protect you against the possibility of electrical shock DO NOT UNDERANYCIRCUMSTANCES REMOVE THE GROUND PIN To reduce the risk of electrical shock a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter GFCI in accordance with national electrical ...

Page 2: ...imitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS Bef...

Page 3: ...120 18 ft 5 5m 38 14 30 144 53 114 20 10 0 GALLONS LITERS 0 5 50 40 30 80 160 FLOW PER MINUTE 105 110 80 60 70 240 131 PUMP PERFORMANCE CURVE 104 105 110 115 120 131 132 4 TOTAL DYNAMIC HEAD 2 10 15 6 20 FEET METERS 25 115 120 104 132 1 DO read all installation material included with the pump 2 DO inspect unit for any visible damage caused by shipping Contact dealer if unit appears to be damaged 3...

Page 4: ...de standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS Figu...

Page 5: ...tream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Foam Gasket 3 1 Install the foam gasket into the gasket seat at the top of the basin refer to Figure 3 1 for details Figure 3 1 OVERLAP DETAIL GASKET SEAT FOAM GASKET GASKET SEAT DETAIL FOAM GASKET APPROXIMATELY 1 4 OVERLAP BASIN SK2003 ...

Page 6: ...llation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in the...

Page 7: ...ap rotate the tail pipe to the orientation shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the opening and install the cordseal as shown in Figure 5 3A Insure o ring is in the cap before installation 5 3 Place the basin assembly in its final position and complete plumbing Secure all connections shown in 5 3A or 5 3B STEP 6 Initial Testing ...

Page 8: ... N A 2 Md M72 See FM1722 1 N A N A 72 0001 Md M53 See FM0472 007917 N A N A M55 See FM0537 007918 N A N A M57 See FM0431 007919 N A N A M59 See FM0432 007920 N A N A M98 See FM1032 N A 007921 N A 3 Basin Tank 1 013017 013017 013017 4 Discharge Tube 1 013732 014759 013732 5 Basin Lid 1 013018 013018 013018 6 Hardware Pack 1 013731 013731 013731 7 Basin Seal 1 N A N A N A 8 Unicheck 1 30 0181 30 018...

Reviews: