PUMP ELECTRICAL CONNECTIONS

CONTINUED

2.  Insert an electrical wire strain relief into the opening in the side of the pressure switch closest to the motor (Fig. 2).
3.  Thread the cable from the pump motor through the strain relief into the pressure switch cavity and tighten both screws on the strain relief. Do not 

crush wire (Fig. 3).

4.  Connect the two motor wires of the motor cable to the two inside terminals on the pressure switch (Fig. 4).
5.  Connect the green ground wire from the motor cable to one of the green ground screws at the bottom of the pressure switch (Fig. 5).

IL1372

2

IL1373

Wire from 

motor

3

IL1374

Wire from 

motor

4

IL1375

Wire from 

motor

Ground Screws

5

IL1376

Wire from 

motor

6

IL1377 

Wire from 

motor

Wire from 

power

supply

7

IL1378

Wire from 

motor

Wire from 

power

supply

8

IL1379

Wire from 

motor

Wire from 

power

supply

Ground Screws

9

6.  Insert an electrical wire strain relief into the opening in the opposite side of the pressure switch (Fig. 6).
7.  Thread the cable from the power supply through the strain relief and tighten both screws on the strain relief. Do not crush wire (Fig. 7).
8.  Connect the two wires from the power supply to the two outside terminals on the pressure switch (Fig. 8).
9.  Connect the green ground wire from the power supply to the remaining green ground screw in the pressure switch and re-attach the 

pressure switch cover (Fig. 9).

10

11a

11b

11c

To change from 115V to 230V
10.  The motor of this pump is dual voltage and can run on either 115V or 230V. In general, 230V is more economical to run, and requires a smaller 

wire size. The 1/2 HP model is factory preset to run at 115V (Fig. 10).  
NOTE: 1 HP models are factory preset to operate at 230V. 

11.  For 230V service, change the following wires on the terminal board:

a.  Using a pair of needle nose pliers, pull the gray wire with the female flag connector from the “A” terminal spade post. Place it to the right 

on the “B” terminal space post (Fig. 11a).

b.  Pull the red wire with the female flag connector from the “L2” terminal. Place it to the left on the “B” terminal space post (Fig. 11b).
c.  Reinstall the rear motor cover (Fig. 11c).

 NOTE: To change 1 HP models to 115V, simply reverse instructions above. 

IL1372

IL1373

IL1374

IL1375

IL1376

IL1377

IL1378

IL1379

IL1354A

IL1355A

IL1356A

IL1270

Summary of Contents for 023072

Page 1: ...OUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP MAINTAIN ALL SAFETY DECALS Table of Contents Safety Instructions 1 Limited Warranty 2 Preinstallation Information 2 3 Installation Procedures 4 7 Parts List 7 Troubleshooting Checklist 8 Congratulations on the purchase of the Zoeller Potable Water ConvertibleJetPump Since1939 thenameZoellerhasrepresented the stan...

Page 2: ... EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Some states do not allow limitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above ...

Page 3: ...d by wiring the unit to a ground metal clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means 6 Hazardous Pressure Install pressure relief valve in discharge pipe Release all pressure on system before working on any component 7 Do not use to pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in...

Page 4: ... and in accordance with local and state codes PIPING 1 Old or badly scaled pipe should not be used because dislodged flakes of scale can cause stoppage of the ejector nozzle and malfunction the entire system 2 Use only pipe in good condition free from rust and scale Threads should be sharp cleanly cut with a minimum of two 2 threads remaining when connection is completely drawn up 3 On galvanized ...

Page 5: ...in bushing steel 3 Pressure Gauge 4 Pump stand for tank 5 Well adapter for single pipe packer installations straight and right angle shown NOTE For a successful installation take time to study your application for the correct pipe size and appropriate fittings The illustrations in these instructions will assist you with required and optional fittings Sch 40 PVC plastic pipe and fittings were used ...

Page 6: ...le Pipe System Where water level is greater than 25 feet and inside diameter of well is 4 or larger 1 Attach the foot valve to the ejector using a galvanized steel or plastic nipple Add enough 1 in pressure pipe and 1 1 4 in suction pipe to submerge ejector 10 to 15 below pumping water level making certain foot valve is at least five 5 feet from bottom of well If pressure pipe and suction pipe of ...

Page 7: ...the ejector down the casing 3 As each section is lowered check for leaks by pouring water into the suction pipe 4 Attach well adapter to suction pipe lower over casing top and tighten adapter flange 5 If no leaks are found proceed to WELL TO PUMP CONNECTION SUCTION PIPE using piping of the same diameter as the suction pipe 1 1 4 and pressure pipe 1 tappings of the pump For long offset distances se...

Page 8: ...ell with additional pipe and fittings as needed Fig 5 Shallow Well Application Only CAUTION Dry fit entire assembly to ensure proper fit before gluing or taping parts Follow all proper gluing procedures as specified by the glue manufacturer Always glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings Use pipe tape and pipe paste compound on all male t...

Page 9: ...87 5 Glue Deep Well Application Only 1 To begin the connection to the pressure tank loosely assemble flow control body to pump head Using Teflon tape position the discharge outlet of the control body facing right as you look directly into the face of the pump Fig 1 2 Assemble the pressure switch in the 1 4 tapping adjacent and to the right of the discharge outlet of the control valve Fig 2 Refer t...

Page 10: ...m on this page or step by step instructions on page 11 Your pump motor has a built in thermal overload that protects the motor against burnout from overload of low voltage high voltage and other causes The device is automatic and resets itself once the temperature has dropped to a safe point Frequent tripping of the device indicates trouble in the motor or power lines and immediate attention is ne...

Page 11: ...ly through the strain relief and tighten both screws on the strain relief Do not crush wire Fig 7 8 Connect the two wires from the power supply to the two outside terminals on the pressure switch Fig 8 9 Connect the green ground wire from the power supply to the remaining green ground screw in the pressure switch and re attach the pressure switch cover Fig 9 10 11a 11b 11c To change from 115V to 2...

Page 12: ...oming voltage matches the pump wiring voltage See wiring guide in the instructions NOTE Watch for leaks or a milky color in the discharged water which indicates an air leak Make sure foot valve and or check valve is working properly IL1403 IL1404 3 IL1405 4 Deep Well Application Only CAUTION All pumps must be primed filling the cavity with water before they are first operated This may take several...

Page 13: ... the pump is being used for shallow well applications the flow control screw should be set in the full open position IMPORTANT If the pump fails to prime within five minutes Turn power off at the breaker box Look for leaks or a milky color in the discharged water which indicates an air leak Re prime if necessary following steps 1 through 5 above Reset breaker at the breaker box All connections mus...

Page 14: ...p of liquid soap to the inside diameter of the rubber drive ring 7 Replace the impeller and diffuser removed in Steps 2 3 8 Reassemble the pump body to the motor and mounting bracket MOTOR REPLACEMENT Figure 5 1 Uni Frame motors can be replaced in the field with any standard Nema J jet pump motor by following the instructions below CAUTION Before attempting to replace the motor make certain that t...

Page 15: ...ing Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Control Assembly Control Body Flow Control Screw Pump Body Plug 1 4 NPT Pressure Switch Cap Screws 3 8 x 3 4 Base Lead Wire 1 1 1 1 1 1 1 1 1 1 1 3 1 8 1 1 98J105 134162 132583 131100 139349 132424 132428 134349 135019 124330 134121 020345 128034 136135A 98J110 134163 132429 131100 134138 132425 132428 134349 135019 124330 ...

Page 16: ...ecessary 3 Rearrange piping to eliminate air lock 4 Replace undersized piping or install pump with higher capacity 5 Tighten all fittings and replace control if necessary 6 Make sure above ground connections are tight Repeat test If necessary pull piping and repair leak 7 Close down the valve on discharge side of pump to limit flow of water in keeping with well capacity 8 Clean and reinstall if di...

Reviews: