H0439100.C - EN - 2015-01
4
EN
The heat pump can be fixed to the ground using the brackets at the base of the unit (attachments not included).
A diagram for drilling is featured on the back of the packing box.
2.3 Hydraulic connections
V1-2-3 : by-pass valves
V4 : water intake valve
V5 : water output valve
* minimum distance
Z300
M4
M5
T5
MD5
TD5
M7 MD8
TD8
Test pressure
bar
3
Service pressure
bar
1,5
Load loss
mCE 1,4
1,5
1,5
1,1
Mean water
flowrate
m³/h
4
5
6
6,5
Follow the hydraulic connection direction
(see § «Dimensions» in the appendix).
• The connection include a Ø 50 PVC rigid pipe, from a by-pass, on the swimming pool filtration circuit, after the filter and
before any water treatment unit.
• Installing a by-pass is mandatory and facilitates operations on the appliance.
• Adjust the water flow using valve V1, and leave valves V2, V3, V4 and V5 open.
• Make sure the hydraulic fittings are correctly tightened and that there are no leaks.
Disposing of condensation:
Warning: your device can produce several litres of water per day. It is strongly recommended to guide the flow to
drains.
• Connect a Ø18 interior pipe (not supplied), to the grooved end-piece mounted on the base of the appliance,
• Outlet: to the back or on the side :
2.4 Electrical connections
2.4.1 Voltage and protection
• The electrical supply to the heat pump must include a protection and circuit-breaker device (not supplied) complying
with the standards and regulations in force in the country,
• Additional protection may be required during installation to protect against overvoltage category II,
• The device is designed for connection to a general power grid with TT and TN.S grounding systems,
• Electrical protection: circuit-breaker (curve D) (see § 2.4.3 for ratings), and with a 30 mA dedicated differential trip
switch (circuit-breaker or switch).
Fixing holes
2.2 Installing the appliance
• Fit the 5 anti-vibration pads (supplied, see §1.2)
•
Install on a stable, solid surface
(concrete slab for example) which is level
,
• Protect from risks of flooding due to condensates from the appliance when it is running (see §2.3).
Summary of Contents for Z300 Series
Page 13: ...Notes ...
Page 25: ...Notes ...
Page 37: ...Notes ...
Page 49: ...Notes ...
Page 61: ...Notes ...
Page 73: ...Notes ...
Page 85: ...Notes ...
Page 87: ...H0439100 C ML 2015 01 2 Z300 T5 ...
Page 88: ...H0439100 C ML 2015 01 3 Z300 MD5 ...
Page 89: ...H0439100 C ML 2015 01 4 Z300 MD8 ...
Page 90: ...H0439100 C ML 2015 01 5 Z300 TD5 TD8 ...
Page 95: ......