![background image](http://html1.mh-extra.com/html/zodiac/z300-series/z300-series_instructions-for-installation-and-use-manual_936154016.webp)
H0439100.C - EN - 2015-01
3
1. Information before installing
1.1 General delivery terms and conditions
All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The latter must make
written reserves on the transporter’s delivery documents if damage during transport is discovered (confirmed by
registered letter to the transporter within 48 hours).
The device must be transported and stored upright on its pallet in its original packaging.
If the appliance has been tipped over, make written reserves to the transporter.
1.2 Content
Z300
Wintering cover
Wintering Cap
In a bag in the technical compartment
Anti-vibration pads
Fitting Ø50
Cable gland
x1
x1
x2
x5
x2
x1
1.3 Technical specifications
Z300
Voltage
Input power*
Rated input
intensity*
Defrosting by
forced ventilation
Defrosting by cycle
inversion
St
andar
d
M4
230V-50Hz
1.70 kW
7.9 A
X
M5
230V-50Hz
2.20 kW
10.3 A
X
T5
400V-50Hz
2.20 kW
4.25 A
X
M7
230V-50Hz
2.88 kW
13 A
X
Re
ver
sible
MD5
230V-50Hz
2.20 kW
10 A
X
X
TD5
400V-50Hz
2.26 kW
4.4 A
X
X
MD8
230V-50Hz
3.50 kW
16 A
X
X
TD8
400V-50Hz
3.50 kW
7.4 A
X
X
* with ambient air at +15 °C, pool water at 26 °C, and relative humidity of 70% (according to French standard NF-414)
• class: I,
• degree of pollution: 2,
• overvoltage category: II
Operating range:
• air temperature of between 5 °C and 38 °C for standard models,
• air temperature of between -8 °C and 38 °C for reversible models,
• water temperature of between 10 °C and 32 °C,
Maximum temperature setting of 32°C to protect the pool lining.
2. Installation
Do not take grip on the outer casing to pick up the device, hold the base.
2.1 Selecting an installation site
The device must be installed outdoors and there must be adequate open space surrounding it (see §2.3).
•
The heat pump must be installed
at a minimum distance from the edge of the pool in order to avoid any projections of
spray onto the appliance. This distance is determined by the electric standards applicable locally.
•
The heat pump must not be installed:
-
close to a heat source or to a source of inflammable gas,
-
close to a road with a risk of water or mud being sprayed,
-
facing strong winds,
-
with the blower facing a permanent or temporary obstruction (window, wall, hedge, etc.) less than 4 metres away.
Summary of Contents for Z300 Series
Page 13: ...Notes ...
Page 25: ...Notes ...
Page 37: ...Notes ...
Page 49: ...Notes ...
Page 61: ...Notes ...
Page 73: ...Notes ...
Page 85: ...Notes ...
Page 87: ...H0439100 C ML 2015 01 2 Z300 T5 ...
Page 88: ...H0439100 C ML 2015 01 3 Z300 MD5 ...
Page 89: ...H0439100 C ML 2015 01 4 Z300 MD8 ...
Page 90: ...H0439100 C ML 2015 01 5 Z300 TD5 TD8 ...
Page 95: ......