background image

 

 

H03818-00.A3 EN – 2012-03

 

 

 

5. Replacing the Tyres on the Cleaner 

 

 

Pull on the inside of the

 

old tyre to remove the tyre lip from the wheel 

(1).

 

 

Remove the old tyre 

(2).

 

 

To replace the tyre, position the tyre on the wheel making sure to orient the tyre so that the tyre tread is on the 
outer side of the wheel 

(3).

 

 

 

Push one side of the tyre on to the wheel and fit the rib of the tyre in the groove of the wheel 

(4).

 

 

Work the tyre onto the wheel and verify the rib of the tyre is positioned properly within the groove of the wheel 

(5).

 

 

Push and position the rib of the inner side of the tyre in the groove of the wheel 

(6). 

If needed, turn the wheel 

gently to help with installation.

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 
 
 
 

6. Troubleshooting 

 
 

Symptom 

Cause 

Solution 

 
 
 
 
 

The flashing indicator lights 
appear just after start (pressing 
the Power or Cycle button to 
start the cleaner) (< 20 seconds).

 

Floating cable is not properly 
plugged into the control unit.

 

Unplug the floating cable from

 the 

control unit and plug it again properly.

 

Cleaner is not well submerged.

 

Submerge the cleaner following the 
procedure in Section 2.2, "Submerging 
the Cleaner".

 

Cleaner needs to be reset and start 
new cycle.

 

Press the power button OFF and then 
Cycle

 

I or II Program buttons to start 

new cycle.

 

Propeller does not turn.

 

Please contact your local 

service 

representative.

 

Wheels do not turn.

 

Please contact your local 

service 

representative.

 

 

The flashing lights appears during 
the cycle.

 

If the cleaner

 sucks air for 60 

seconds, the flashing light appears.

 

Submerge the cleaner following the 
procedure in Section 2.2, "Submerging 
the Cleaner".

 

 

 

The word "inside" is imprinted on the rim of the tyre. Make sure the word "inside" is facing towards the 
body of the cleaner. 

 

 

 

 

 

 

Summary of Contents for V3

Page 1: ...EN...

Page 2: ...er to the installation instructions relating to the swimming pool equipment for which the cleaner will be an integral part The cleaner is to be supplied through a Residual Current Device RCD with a ra...

Page 3: ...before removing it from water and do not operate out of water Do not remove the cleaner from the pool for 15 minutes after the cleaning cycle has completed Clean filter canister in the cleaner after e...

Page 4: ...n the cart as shown 1 Make sure the upper tubes handles are in the proper orientation and align the screw holes Position the bottom power cable hook as shown 2 Place the cable hook plate opposite the...

Page 5: ...s to the caddy using four screws V3 figure 9 V3 4WD figure 10 The transport caddy is now ready to use 1 4 Connecting the control unit to the caddy Position the control unit over the control unit hook...

Page 6: ...re starting a cleaning cycle Do not leave the cleaner in the water permanently Stow your cleaner on its caddy as soon as possible after use in order to avoid distorting the flexible edge at the openin...

Page 7: ...When the cleaner is powered ON it will remain in standby until the Cycle I button is pressed 1 When the Cycle I program button is selected the indicator light above will illuminate The cleaner will s...

Page 8: ...t the cover 2 until it is secured in the vertical position Figure 1 Remove the filter assembly from the body 3 Figure 2 Push the quick release button on the canister assembly 4 and pull open the filte...

Page 9: ...es as soon as one of the wear indicators has been reached even if the blade wear is not even It recommended to replace the brushes every two 2 years Lift the cleaner to a vertical position so that the...

Page 10: ...s appear just after start pressing the Power or Cycle button to start the cleaner 20 seconds Floating cable is not properly plugged into the control unit Unplug the floating cable from the control uni...

Page 11: ...trike Symptom Cause Solution The cleaner does not stay firmly on the pool bottom There is air in the appliance casing Submerge the cleaner following the procedure in Section 2 2 Submerging the Cleaner...

Page 12: ...and obtain a warranty ID number for the warranty claim Contact details are Zodiac Group Australia Pty Ltd Customer Service 219 Woodpark Road Telephone 1800 688 552 Smithfield NSW 2164 Email address a...

Page 13: ...Notes...

Page 14: ...Notes...

Page 15: ...Notes...