3
H0360700.D - EN - 2016-02
❶ Specifi cati ons
1.1 I Descripti on
A
UAP
B
Ø50 connector to be glued + seal x2
C
Pin to be soldered Ø20/22 (UAP 35-75-120) - Ø26/28 (UAP 240) x2
D
UAN
1.2 I Technical specifi cati ons
UAP / UAN
Unit
35
70
120
240
Primary
°C
90
60
45
90
60
45
90
60
45
90
60
45
Secondary
°C
26
26
26
26
Power
kW
55
27
15
80
38
21
120
63
34
240
123
68
Primary rate
m³/h
1.6
2.1
2.8
6.3
Secondary rate
m³/h
2
2.9
4.3
8.7
Primary loss of load
bar
0.15
0.12
0.1
0.2
Secondary loss of load
bar
0.24
0.23
0.25
0.38
Primary pressure head
available*
bar
0.23
0.2
0.07
0.16
Primary connecti on
UAP
Ø26/34 male screw-in
Ø33/42 male screw-in
UAN
Ø20/27 male screw-in
Ø26/34 male screw-in
Secondary connecti on
UAP
PVC Ø50 to be glued
UAN
Ø20/27 male screw-in
Ø26/34 male screw-in
Primary circuit pressure
Service
2 bars
Maximum
3 bars
Number of plates
11
17
31
31
Type of ti tanium plate
T2B
M3 MH/ML
Plate thickness
mm
0.5
0.4
Medium ti ghtening
dimension
mm
34
53
96
87
Operati ng temperature
range
Pool water
between 2 and 40 °C
Primary
circuit
water
between 45 and 90 °C
UAP
35
70
120
240
Electrical box protecti on index
IP34
Power supply
230Vac
Circulati ng pump
Alpha 2L 15-60
Magna 1 32-80
Circulati ng pump spacer
130 mm
180 mm
Absorbed power
Speed 3
45 W
151 W
In
0.20 A
0.65 A
Maximum absorbed intensity
0.38 A
1.22 A
or
EN