❹ Maintenance
4.1 I Wintering
•
Wintering is vital to prevent the condenser breaking due to freezing. This is not covered by
the warranty.
•
To avoid damaging the electrical box with condensati on, do not fully cover it.
•
Power down the regulati on,
•
Cut the water circulati on in the primary and secondary circuits,
•
Drain the primary circuit (pay att enti on to the water temperature; wait unti l it cools down to avoid any risk of burns):
-
Close the insulati on valves D and E (see § “2.2 I Hydraulic connecti ons”),
-
Open the drainage valve,
•
Drain the secondary circuit:
-
Close valves A and C (see § “2.2 I Hydraulic connecti ons”),
-
Unscrew the connectors to drain the exchanger,
-
Tighten the connectors slightly again when the exchanger is empty.
4.2 I Maintenance
•
It is recommended that the device be general serviced at least on a yearly basis to ensure
proper operati on, maintain performance levels and prevent some potenti al failures. These
operati ons are carried out at the user's expense, by a technician.
4.2.1 Maintenance to be carried out by a qualifi ed technician
•
Make sure that the appliance's pipe fi tti ngs are property ti ghtened.
•
Only for UAP:
-
Check the electrical mechanism.
-
Check the ground connecti on.
-
Check that the electrical cables are correctly ti ghtened and connected and that the electrical unit is clean.