WARNINGS

•  Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, 

even death.

•  

The appliance is intended for a specifi c pool use and must not be used for any use other than that for which 

it was designed.

•  

It is important that the equipment is operated by competent and qualifi ed (both physically and mentally) 

people who have previously received the instructi ons for use. All persons not meeti ng these criteria must not 

approach the appliance in order to avoid exposure to dangerous elements.

•  Keep the appliance out of the reach of children.

•  

The  device  must  be  installed  by  a  qualifi ed  technician  according  to  the  manufacturer’s  instructi ons  and 

in compliance with local regulati ons. The installer is responsible for installati on of the equipment and for 

compliance with nati onal installati on regulati ons. Under  no circumstances  can the  manufacturer  be  held 

liable in the event of failure to comply with applicable local standards.

•  

Incorrect installati on and/or use may cause serious damage to property or serious injuries (possibly causing 

death). 

•  All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The consignee 

shall make reservati ons in writi ng on the carrier's bill of lading if damage is detected, caused during transport 

(confi rmati on to be sent to the carrier within 48 hours by registered mail with acknowledgement of receipt). 

In the event of a device containing coolant that has been turned on its side, menti on your reservati ons in 

writi ng to the carrier.

•  

If the appliance suff ers a malfuncti on, do not try to repair the appliance yourself, contact a qualifi ed technician.

•  

Refer to the warranty conditi ons for details of the permitt ed water balance values for operati ng the appliance.

•  

Eliminati ng or shunti ng one of the safety devices automati cally voids the warranty, as does the replacement 

of parts using parts not manufactured by ourselves.

•  

Do not spray insecti cide or any other chemical (infl ammable or non-infl ammable) in the directi on of the 

appliance, as this may damage the body and cause a fi re.

•  

The electrical supply to the appliance must be protected by a dedicated 30 mA diff erenti al residual current 

protecti on device, complying with the standards and regulati ons in force in the country where it is installed.

•  

Before carrying out any operati ons, check that:

 

-

The voltage indicated on the maker's plate of the appliance corresponds to the mains voltage, 

 

-

The power grid is adapted to the power requirements of the appliance, and is grounded. 

 

-

The plug (where applicable) is suitable for the socket.

•  

In the event of abnormal functi on or the release of odours from the appliance, turn it of immediately, unplug 

it from its power supply and contact a professional.

•  

Before any interventi on on the appliance, ensure that the latt er is switched off  and disconnected from the 

power supply, in additi on to any other equipment connected to the appliance, and that the heati ng priority 

(where applicable) is deacti vated.

•  

Do not disconnect and reconnect the appliance to the power supply when in operati on.

•  Do not pull on the power cord to disconnect it from the power supply.

•  Do not handle the electrical elements with wet hands.

•  

Clean the terminal board or the power supply socket before connecti on.

•  

For any component or sub-assembly containing a batt ery: do not recharge or dismantle the batt ery, or throw 

it into a fi re. Do not expose it to high temperatures or direct sunlight.

•  

In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.

•  

Do not immerse the appliance in water (with the excepti on of cleaners) or mud.

Recycling

This symbol means that your appliance must not be thrown into a normal bin. It will be selecti vely collected for the 

purpose of reuse, recycling or transformati on. If it contains any substances that may be harmful to the environment, 

these will be eliminated or neutralised.

Contact your dealer for recycling informati on.

EN

Summary of Contents for Uranus+

Page 1: ...H0360700 D 2016 02 Instructions for installation and use English More documents on www zodiac poolcare com Uranus EN ...

Page 2: ...the replacement of parts using parts not manufactured by ourselves Do not spray insecticide or any other chemical inflammable or non inflammable in the direction of the appliance as this may damage the body and cause a fire The electrical supply to the appliance must be protected by a dedicated 30 mA differential residual current protection device complying with the standards and regulations in force ...

Page 3: ...you do anything with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will invalidate the warranty Keep and pass on these documents for later consultation during the device s life time It is prohibited to distribute or modify thi...

Page 4: ...6 Primary connection UAP Ø26 34 male screw in Ø33 42 male screw in UAN Ø20 27 male screw in Ø26 34 male screw in Secondary connection UAP PVC Ø50 to be glued UAN Ø20 27 male screw in Ø26 34 male screw in Primary circuit pressure Service 2 bars Maximum 3 bars Number of plates 11 17 31 31 Type of titanium plate T2B M3 MH ML Plate thickness mm 0 5 0 4 Medium tightening dimension mm 34 53 96 87 Operat...

Page 5: ...H0360700 D EN 2016 02 4 1 3 I Dimensions and marking UAP 35 70 120 UAP 240 ...

Page 6: ... mm 240 407 mm 350 mm 500 mm 1 87 mm 200 mm 70 mm 60 mm 71 5 mm 357 mm Electrical unit Spherical valve Fixed chassis Circulating pump Tightening plate Drainage valve Exchange plates Anti return valve Adaptation and sealing flange Injected T with spur 20 27 male screw in Rate controller Connection tubes with caps Adaptation and sealing flange Injected T with spur 20 27 male screw in Regulation sensor...

Page 7: ...if the floor is cleaned with a water spray 2 2 I Hydraulic connections Respect the hydraulic connection direction see the label on the appliance Do not use quick closure valves to avoid water hammer Correctly tighten the hydraulic connections and check for leaks Check that the pipe system is cleaned before connecting anything pool water inlet valve secondary circuit pool water by pass valve seconda...

Page 8: ... a protected power socket near the appliance from an approved technician If the supply cable is not long enough it must be replaced by a qualified technician The electricity supply cable must be insulated against any cutting or hot elements that may damage or crush it The equipment must be connected to an earth socket The electrical connection lines must be fixed 2 3 1 Connecting an external command...

Page 9: ...erface presentation depending on the models Display screen default water temperature measured On off button Value setting buttons Fixed Flashing Off On off light Appliance powered up No electrical supply Heating light Heating in progress Timed before operation No water circulation in the secondary circuit less than 1 1m h No need for heating Tips using the user interface The temperature is regulated ...

Page 10: ...ry out a first by pass setting by slightly closing valve 1 150 to 200g for Uranus 35 70 300 to 400g for Uranus 120 240 on the filter pressure so that the nominal secondary water flow is more or less respected Open valves D and E fully Check that the heating circuit is filled and vented Connect the regulation to the power supply and turn it on Adjust the temperature setpoint Adjust the by pass using va...

Page 11: ...ating pump operating modes on UAP 35 70 120 3 4 3 Circulating pump operating modes on UAP 35 70 120 Press to scroll through the operating modes Mode Speed Lights Proportional pressure Speed 1 Speed 2 Constant pressure Speed 1 Speed 2 Constant speed Speed 3 Speed 2 Speed 1 3 4 4 Operation of the circulating pump on UAP 240 When the circulating pump is powered up the light comes on green When the ci...

Page 12: ...irculating pump operating modes on UAP 240 Press to scroll through the operating modes Mode Speed Lights Proportional pressure Speed 1 Speed 2 Speed 3 Constant pressure Speed 1 Speed 2 Speed 3 Constant speed Speed 3 Speed 2 Speed 1 EN ...

Page 13: ...ondary circuit Close valves A and C see 2 2 I Hydraulic connections Unscrew the connectors to drain the exchanger Tighten the connectors slightly again when the exchanger is empty 4 2 I Maintenance It is recommended that the device be general serviced at least on a yearly basis to ensure proper operation maintain performance levels and prevent some potential failures These operations are carried o...

Page 14: ...at the water is circulating correctly in the appliance It may be that the appliance has detected an operating fault see 5 2 I Error code display The device is working but the water temperature does not increase It may be that the appliance has detected an operating fault see 5 2 I Error code display Check that the automatic filling valve is not stuck in open position this will keep supplying cold w...

Page 15: ...e fuse T3 15AH250V 5 4 I Wiring diagrams CA power cable 2L E 10 16A 3G1 TH Regulation thermostat with digital display M1 Circulating pump motor F1 3 15 A T protection fuse CD Flow controller So Pool water regulation sensor PTC GN Black duct L1 On off LED L2 Reg LED flashing when timed or fixed heating in progress S1 On off switch 19 20 Dry command contact normally open V J Green yellow Bl blue M brown...

Page 16: ... 49180 St Barthélémy d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Modèle appareil Appliance model Numéro de série Serial number Trouvez plus d informations et enregistrez votre produit sur More informations and register you product on www zodiac poolcare com ...

Reviews: