background image

THANK YOU FOR PURCHASING THIS ROBOTIC POOL CLEANER BY ZODIAC

®

.

YOUR CLEANER HAS BEEN DESIGNED AND MANUFACTURED TO BE EASILY INSTALLED AND TO PROVIDE 

LOW MAINTENANCE OPERATION.  PRIOR TO INSTALLING YOUR NEW CLEANER, PLEASE DO THE 

FOLLOWING:

1) 

Complete and return the warranty card.

2) 

Record your purchase information on the spaces provided below.

3) 

Attach your invoice (or a copy) to this page.

Taking these steps will help ensure prompt warranty service, should it be required. If service is required, please  

contact your original dealer. If the original dealer does not perform warranty service:  

Australia and New Zealand 

Please contact Zodiac Customer Care 1300 763 021 or visit 

www.zodiac.com.au

 

South Africa

 Please contact Zodiac Customer Care 0860 887 665 or visit 

www.zodiac.co.za

In the case that your product may require a warranty or service, please retain the original carton to transport your 

cleaner in.

RECORD YOUR ZODIAC CLEANER DATA HERE:

Date of Purchase    

Purchased From      Serial Number: 

   

       

    

(located on machine head)

City 

     State  

    Postal Code  

 

Section 1.  Important Safety Instructions ........ 3

Section 2.  Getting Started ................................ 4

2.1  General Specifications  ...................................... 4
2.2 Unpacking .......................................................... 4
2.3  Cleaner Control Unit ........................................... 4
2.4  Connecting to Power Source .............................. 5

Section 3.   Operation ......................................... 6

3.1  Submerging the Cleaner .................................... 6
3.2  Running the Cleaner .......................................... 6
3.3  Stopping the Cleaner  

and Removing from the Pool .............................. 7

3.4  Rinsing the Cleaner ............................................ 7
3.5  Cleaning the Filter Canister ................................ 7
3.6  Storing the Cleaner  ........................................... 8

Table of Contents

Section 4.  Maintenance .................................... 9

4.1  Cord Tangling 

 ........................................................................... 9

4.2  Replacing the Brushes ....................................... 9
4.3  Replacing the Track .......................................... 10

Section 5.  Troubleshooting ........................... 10

5.1  Using the Information LED ............................... 10
5.2  General Troubleshooting .................................. 10

Summary of Contents for TX20

Page 1: ...ed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist In the event no such state or local requirement exists the ma...

Page 2: ...ac Customer Care 0860 887 665 or visit www zodiac co za In the case that your product may require a warranty or service please retain the original carton to transport your cleaner in RECORD YOUR ZODIA...

Page 3: ...nt To reduce the risk of electrical shock do not use the robotic cleaner or control unit if the cord is worn or damaged Immediately contact Zodiac Customer Care Service for proper servicing and replac...

Page 4: ...two 2 layers of insulating material surrounding live parts or by using reinforced insulation Therefore devices having double insulated construction such as this cleaner do not require a grounded thre...

Page 5: ...nstructions relating to the swimming pool equipment for which the cleaner will be an integral part The cleaner is to be supplied through a Residual Current Device RCD with a rated residual operating c...

Page 6: ...aner includes a safety feature that automatically stops the cleaner if it is powered on but not submerged in water For pools equipped with a beach area this safety feature is programmed to drive the c...

Page 7: ...ce 1 Unplug power to the cleaner at the control unit Turn off power then unplug the control unit from the power source 2 Press the Push n Go button to release the filter canister handle Figure 7 Figur...

Page 8: ...any kinks and coils from the power cable starting at the cleaner head 2 Store the cleaner out of direct sunlight FX35 models It is recommended when storing the cleaner for extended periods use the Zo...

Page 9: ...t sunlight for next use Figure 13 Untangle the Power Cord 4 2 Replacing the Brushes The cleaner is fitted with PVC brushes in front and rear There are wear indicators Figure 14 on the brushes To maint...

Page 10: ...ation LED on the control unit flashes in a specific sequence to indicate one of three possible cleaner malfunctions LED Flashing Solution 1 Flash LED flashes once with one second interval Unplug the f...

Page 11: ...slippery and prevent the cleaner from climbing Check tracks for wear and replace as necessary Do a shock chlorination treatment to reduce the pH levels in the pool DO NOT leave the cleaner in the pool...

Page 12: ...ZODIAC is a registered trademark of Zodiac International S A S U used under license All other trademarks used herein are the property of their respective owners 2017 Zodiac Pool Systems Inc H0585900...

Reviews: