3
English
U-N
single phase main supply 230Vac-1N-50Hz
U-V-W-N three phase main supply 400Vac-3N-50Hz
PE
Earth
N
black
B blue
M
brown
B1
command logic controller ECP 600
SD1
air inlet sensor (black sheath)
SD2
defrost sensor (grey sheath)
5-7-2-4-1 connection of Hygro Control (sie §1.3.7.4)
26-27
supply (230 V AC -50 Hz) for remote fault warning light or relaying
3-6
control of heating for PSA type boiler or an existing heating system
C-C
supply (230Vac-50Hz) for battery circulator or used for electric logic of the heating option
by electric backing
E1
high pressure switch
E2 low
pressure
switch
OAE
back up heating option
R heating
resistor
THS
high limit thermostat (automatic reset)
THSM
positive high limit thermostat (manual reset)
M1
ventilator motor (230Vac/50Hz)
M2 compressor
motor
(230Vac/50Hz)
KM1
power contactor of back up heating resistor
KM2
compressor power contactor
KA4
starting relay or phase order relay on Sirocco three phase
F2
Compressor internal thermal protection
C1
ventilator capacitor
C2
compressor capacitor
C3
filtering capacitor
C4
starting relay capacitor
Summary of Contents for SIROCCO 110
Page 21: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Page 22: ...1 Electric diagram Sirocco 55 80 110 single phase...
Page 23: ...2 Sirocco 110 three phase...
Page 26: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Page 27: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...