12
1.3.8 Connection of the options
1.3.8.1 Hot water battery
Connections on Ø15-21, male fitting. Outlet must be
obligatorily on the left
seen from the front.
Power
Water flow rate
Water load loss
Unit
kW
m³/h
mCE
Primary
90/70°C
45/40°C
90/70°C
45/40°C
90/70°C
45/40°C
Sirocco 55
6 2.1
0.25
0.35
0.41
0.77
Sirocco 80
9
2.6
0.42
0.46
0.37
0.47
Sirocco 110
12 3.3 0.53
0.58
0.65
0.83
Water temperature input to the hot water battery: 45 °C minimum, 90°C maximum.
Maximum pressure water battery circuit: 3 bars
Power returned to the air at 27°C input to the hot water battery.
Connection to the primary circuit: before any valves or pumps
.
Swimming
pool hall
Technical
room
Swimming
pool hall
Technical
room
Circulator main
supply cable
Circulator main
supply cable
Sirocco ambient
Suction
Blowing
Sirocco can be inset
Suction
Blowing
EN
Automatic purge
Circulator
Check valve or
solendoid valve
Check valve or solendoid
Automatic purge
Circulator
Check valve or
solendoid valve
Check valve or
solendoid valve
Summary of Contents for SIROCCO 110
Page 21: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Page 22: ...1 Electric diagram Sirocco 55 80 110 single phase...
Page 23: ...2 Sirocco 110 three phase...
Page 26: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Page 27: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...