background image

2

CONTENTS

❶ SPECIFICATIONS

 

3

1.1 I  Description

 

3

1.2 I  Technical specifications

 

3

1.3 I  Dimensions and marking

 4

❷ INSTALLATION

 

5

2.1 I  Selecting the location

 

5

2.2 I  Assembling the filter

 

6

❸ USE

 9

3.1 I  Operating principle

 9

3.2 I  Multiway valve positions

 9

3.3 I  Operation

 11

❹ MAINTENANCE

 

12

4.1 I  Winterizing

 

12

4.2 I  Maintenance

 

12

❺ TROUBLESHOOTING

 

13

• 

Before handling the appliance, it is essential that you read this installation and user manual, 

as well as the "warnings and warranty" booklet delivered with the appliance. Failure to do so 

may result in material damage or serious or fatal injury and will void the warranty.

• 

Keep these instructions for future reference for operation and maintenance works.

• 

The  distribution  or  modification  of  this  document  in  any  way  is  prohibited,  without  prior 

authorisation from Zodiac®.

• 

Zodiac®  is  constantly  developing  its  products  to  improve  their  quality.  The  information 

contained herein may therefore be modified without notice. 

Tip: to make it easier to contact your retailer

• 

Write down your retailer's contact details to help you find them more easily and fill in the "product" 

information on the back of the manual; your retailer will ask you for this information.

EN

Summary of Contents for MS FILTER D470

Page 1: ...H0648400_REVB 2018 09 More documents on www zodiac poolcare com Instructions for installation and use English Filter Translation of the original instructions in French EN...

Page 2: ...roperty or serious injuries possibly causing death All equipment even postage and packing paid travels at the risks and perils of the recipient The latter shall issue reserves in writing on the carrie...

Page 3: ...with the appliance Failure to do so may result in material damage or serious or fatal injury and will void the warranty Keep these instructions for future reference for operation and maintenance work...

Page 4: ...D800 D950 Filtering area m 0 16 0 20 0 32 0 47 0 66 Filter media capacity on kg Sand 0 4 0 8 mm 85 100 160 310 485 Thick glass 1 0 3 0 mm 15 15 30 45 60 Thin glass 0 7 1 3 mm 60 75 105 225 345 Flow r...

Page 5: ...ers Drain plug Base Tank Automatic air release Dimension in mm D470 D530 D650 D800 D950 Clearance below valve 310 320 375 390 420 A 340 350 405 430 460 B 465 475 530 660 690 C 529 539 594 736 766 D 70...

Page 6: ...ng lodged in the pipes and with the fewest obstacles possible bends other appliances to avoid head loss Place on a stable level and solid surface e g concrete floor Secure the filter to the ground usi...

Page 7: ...air release onto the large threaded orifice of the T connector Tip installing the bleed screw The bleed screw already contains its own seal do not use Teflon tape to seal Screw the pressure gauge ont...

Page 8: ...ion of the filter Pass a nut around the bent pipe then position the assembly without bonding in this step see image Gently tighten the nut and firmly tighten the nut to obtain perfect alignment betwee...

Page 9: ...nifold and its strainers Level the filter media as it is poured in Then pour in the fine grain filter media up to the required level See the label on the filter for the amounts of filter media to use...

Page 10: ...to the filter media and returned to the pool Pool suction open Pool discharge open Filter inlet or outlet open Discharge to the drainage system closed Position Backwash The filter media is backflushed...

Page 11: ...ilter and sent directly to the pool Pool suction open Pool discharge open Filter inlet or outlet closed Discharge to the drainage system closed Position Closed Water no longer circulates in the multiw...

Page 12: ...ion backwash Start the pump When the filter level is at maximum water comes out of the air bleed screw close the cover air bleed screw Check that there are no leaks on the hydraulic circuit When start...

Page 13: ...in When the water appears clear through the transparent window on the side of the multiway valve switch off the filter pump Set the valve to the rinse position and switch the filtration system back on...

Page 14: ...level see 2 2 3 Filling the filter Replace the damaged manifold and or manifold strainers The pressure gauge needle shakes violently Air leak in the circuit Suction valves half closed Check the connec...

Page 15: ......

Page 16: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...