Installation Requirements
(Field Assembly)
Supplied power 120VAC or 240VAC
Electrical wiring must be in accordance with the latest
edition of the National Electric Code
®
(NEC
®
), ANSI
®
/
National Fire Protection Association
®
(NFPA
®
) 70, or
in Canada, the Canadian Electrical Code (CSA
®
C22.1)
unless local code requirements indicate otherwise.
The heater comes factory-wired intended for use with 240
Vot, 60 Hz A
C fi
eld electrical supply. To use 120 Vot,
60 Hz AC requires changing the position of the voltage
selector board on the power distribution board. This must
be done by a certi ied electrician.
Filter
Filter
Pump
JXi Heater
Electrical
Power Distribution Board
Conversion from 240 VAC to 120 VAC
FOR 120 VAC
FO
R
240
V
AC
10
1
1
10
5