Available
Model Sizes:
200, 260 & 400
K BTU's
Introduction
The Jandy Pro Series JXi pool/spa heater is a blower
assisted, internal combustion chamber, residential
heater.
General
All gas fired appliances require correct installation to assure safe operation.
The requirements for this pool heater include the following:
Indoor vent adapter required for indoor installation.
Must be vented with Type B Double wall for Category 1 venting or stainless steel
vent pipe for Category 3.
Water piping can be Schedule 40 PVC.
Can be wired 120VAC or 240 VAC
The JXi CAN be installed on combustable surfaces.
Field Assembly
- Properly size gas pipe to supply gas from the meter to the heater.
- Gas shut-off valve (ball-cock) must be installed in-line outside of the heater jacket.
- Suitable gas union must be installed to connect gas line to heater outside of the heater jacket.
- Gas sediment trap (drip leg) in gas line between shut-off valve and heater.
- Supplied power 120VAC or 240VAC (as local code requires)
Proper Gas Pipe Sizing
Distance from Gas Meter
Heater
Size
0-50 feet
(0-15 m)
50-100 feet
(15-30 m)
100-200 feet
(30-60 m)
in.
mm
in.
mm
in.
mm
200
1
25
1-1/4
32
1-1/4
32
260
1-1/4
32
1-1/4
32
1-1/4
32
330
1-1/4
32
1-1/4
32
1-1/2
38
400
1-1/4
32
1-1/2
38
1-1/2
38
For LP gas, reduce pipe diameter by one size, but
maintain a minimum 3/4 inch diameter.
Model Numbers JXI200N, JXI200P,
JXI260N, JXI260P, JXI330N, JXI330P,
JXI400N, JXI400P
JXI 400 N
Model
BTU's
Gas Type N= Natural P = Propane
4
Summary of Contents for JXI200N
Page 1: ...1 Workbook JXi Pool Spa Heater...
Page 2: ...2...
Page 23: ...Exhaust Temperature Switch R0524300 Burner R0591700 23...