14
Display
Possible causes
Solutions
Resetting
Error 12
ST5 sensor error
compressor discharge
sensor
Sensor is faulty or offline (J13
connector)
Reconnect or change the sensor Press
Error 13
ST4 sensor fault fluid line
sensor
Sensor is faulty or offline (J16
connector)
Reconnect or change the sensor Press
Error 14
ST1 sensor fault water
intake sensor
Sensor is faulty or offline (J46
connector)
Reconnect or change the sensor Press
4.3 I Additional menus
To access the menu, press
.
To browse the menus and modify the values, press
or
To validate a selection, press
.
To go back in the menus, press
Water temperature on intake
Air temperature
Defrost sensor
Fluid line sensor
Compressor discharge temperature
Compressor operating speed
Ventilator operating speed
Opening of electronic valve
(only accessible to professionals)
Temperature set point
Hysteresis to switch to cooling mode in
relation to the setpoint
Calibration of the ST1 water intake sensor
Calibration of the ST2 air intake sensor
Cooling mode activation
Fixed operating hours counter
Counter with operating hours reset
Activation of continuous screen backlighting
Activation of heating priority mode
“ON” operation of the filtration pump (if P50
= 3)
“OFF” operation of the filtration pump (if P50
= 3)
Only accessible to professionals
Values provided for information purposes, factory settings
EN