11

❸ Maintenance

  

3.1  I  Winterizing

•   Winterizing is vital to prevent the condenser from being damaged due to freezing. This is not 

covered by the warranty.

•  To avoid damaging the equipment with condensation, do not fully cover it; a winterizing cover 

is provided.

• 

Set the regulator to "standby" mode by pressing and holding 

 for 3 seconds and disconnect the power supply, 

•  Open valve B,

• 

Close valves A and C and open valves D and E (if present), 

• 

Make sure that there is no water circulating in the heat pump, 

• 

Drain the water from the condenser (risk of freezing) by unscrewing the two water input and output connectors on 

the back of the heat pump, 

• 

In the case of full winterizing for the pool (complete shutdown of the filtration system, bleed the filtration circuit 

or even pool drainage): tighten the two connectors by one turn to prevent any foreign bodies from getting into the 

condenser, 

• 

In the case of winterizing for the heat pump only (shutdown of the heating only, the filtration keeps running): to not 

tighten the connectors but add 2 caps (provided) on the condenser's water inputs and outputs.

• 

We recommend that you put the aired winterizing micro cover (provided) on the heat pump.

  

3.2  I  Maintenance

•  Before performing any maintenance operation on the appliance, you must disconnect the 

electrical power supply to the appliance as there is a risk of electric shock which may cause 

material damage, serious injury or even death.

•  Do not disconnect the electricity supply when the device is running.
•  If the electric power supply is interrupted, wait a minute before restoring the power.
•  It is recommended that the device be general serviced at least on a yearly basis to ensure 

proper operation, maintain performance levels and prevent some potential failures. These 

operations are carried out at the user's expense, by a technician.

3.2.1 User maintenance

• 

Make sure that the filter is not blocked by any foreign bodies.

• 

Clean the evaporator (for location see § “5.3  I  Dimensions and marking”) using a soft brush and a fresh water spray 

(disconnect the power cable); do not fold over the metal wings, then clean the condensation drainage pipe to remove 

any impurities that may be blocking it. 

• 

Make sure that the electrical unit's ventilation grid is clean.

• 

Do not use a high pressure jet. Do not spray with rain water, salt water or water which is full of minerals.

• 

Clean the outside of the device; do not use any solvent-based products. We can provide you with a specific cleaning 

kit as an accessory: the PAC NET, see § “5.1  I  Description”.

3.2.2 Maintenance to be carried out by a qualified technician

• 

Check that the regulation is operating correctly connected.

• 

Check that the condensation flows correctly when the device is operating.

• 

Check the safety mechanisms.

• 

Check the connection of the metal masses to the earth.

• 

Check that the electrical cables are correctly tightened and connected and that the electrical unit is clean.

Summary of Contents for Heat Select ZS500 MD4

Page 1: ...H0430700_REVJ 2019 04 More documents on www zodiac com Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Page 2: ...ipment even postage and packing paid travels at the risks and perils of the recipient The latter shall issue reserves in writing on the carrier s delivery slip if damage is detected caused during tran...

Page 3: ...the device it is vital that you read this installation and user manual as well as the warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal inju...

Page 4: ...y or any other support The device must not be installed With the blowing towards a permanent or temporary obstacle awning brushwood etc less than 5 metres away Within range of water or mud jets sprays...

Page 5: ...valve water entry adjustment valve optional water exit adjustment valve optional water treatment minimum distance Connection to a standard filtration circuit To evacuate the condensation fit a 18 pip...

Page 6: ...tions in force in the country where it is installed The device is provided for connection to a general power supply with a TT and TN S neutral regime Electrical protection by circuit breaker D curve f...

Page 7: ...kit available as an accessory plastic cover metal support RJ11 RJ45 extension cable For the connection consult the manual supplied with the kit 1 4 2 Heating priority option This function helps to ke...

Page 8: ...t least 12 hours day the longer this time the longer the appliance will have enough operating range to heat up in Smart or Eco Silence mode Cover the basin with a sheet bubble canopy canvas etc to pre...

Page 9: ...and D fully then valve E by half the air which has built up in the heat pump condenser and the filtration circuit will bleed out If valves D and E are not present open valve A wide and close valve C...

Page 10: ...perating speed Operating power V1 100 Smart Boost V2 75 Eco Silence V3 50 Objective Most economical and quietest operation Smart temperature control no intervention is needed to change the operating m...

Page 11: ...fine the time ranges and operating modes by daily or weekly range Water cooling function activated Displays the water flow present or Set the rate using valve E or C if no valve E In this setting phas...

Page 12: ...shock which may cause material damage serious injury or even death Do not disconnect the electricity supply when the device is running If the electric power supply is interrupted wait a minute before...

Page 13: ...t in its defrost cycle this is not normal Switch off and disconnect the heat pump immediately and contact your reseller The device is not working If there is no display check the supply voltage and th...

Page 14: ...ventilator motor Error 06 Compressor supply overheating Machine s rear panel slots blocked Clean the rear panel If problem persists call an approved technician Automatic if fewer than 4 faults per ho...

Page 15: ...n the menus press Water temperature on intake Air temperature Defrost sensor Fluid line sensor Compressor discharge temperature Compressor operating speed Ventilator operating speed Opening of electro...

Page 16: ...15 4 4 I Wiring diagrams 4 4 1 ZS500 MD4 MD5 MD8...

Page 17: ...16 4 4 2 ZS500 TD5 TD8 EN...

Page 18: ...B 50 connector to be glued x2 C Condensation evacuation kit 18 D Winterizing cap x2 E Winterizing cover Heating priority F Kit for remote control G Plant room kit H Condensate pan I PAC NET cleaning...

Page 19: ...ntensity A 10 13 9 6 22 8 Minimum cable section mm 3x2 5 3x2 5 5x2 5 3x6 5x2 5 3G2 5 3G2 5 5G2 5 3G6 5G2 5 Proof pressure Pa 300 000 Service pressure Pa 150 000 Head loss mCE 1 5 Water flow recommende...

Page 20: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...

Reviews: