ZMIO310 Vertical Bus Expansion Module User Manual V1.0
Chapter V Usage Description
5.1.
Power Consumption Calculation Example
For coupler module, here, take ZMIO310-ECAT communication module as the
example.
External ECAT communication module is supplied by DC24V, internal coupler
supplies 5V power for each module, the max output current is 2A. Except itself internal
power consumption 1.6W, and it supplies 8.4W power for each expansion submodule.
Please see below form for reference.
5.2.
IO Starting Number Configuration
5.2.1.
EtherCAT Bus Expansion
If coupler uses ECAT communication module, IO starting numbers of IN input module
and DO/DOP output modules are configured through
“
NODE_IO
” command
, AIO starting
numbers of AD module and DA module are configured through
“
NODE_AIO
” command.
NODE_IO
Grammar
NODE_IO (slot, node) = iobase
Parameters
slot
Controller bus slot No.
Default is 0
node
Device No.
Start from 0, 0-
Model
Description
ZMIO310-ECAT
ECAT communication module 1.6W
ZMIO310-16DI
Input module 0.3W
ZMIO310-16DO
Output module (NPN) 0.3W
ZMIO310-16DOP
Output module (PNP) 0.3W
ZMIO310-4AD
AD module 0.4W
ZMIO310-4DA
DA module 0.3W
…
…