ZMIO310 Vertical Bus Expansion Module User Manual V1.0
DIP 1-4
combination value
Starting AD
number
End AD
number
Starting DA
number
End DA
number
0
8
15
4
7
1
16
23
8
11
2
24
31
12
15
3
32
39
16
19
4
40
47
20
23
5
48
55
24
27
6
56
63
28
31
7
64
71
32
35
8
72
79
36
39
9
80
87
40
43
10
88
95
44
47
11
96
103
48
51
12
104
111
52
55
13
112
119
56
59
14
120
127
60
63
15
128
135
64
67
→
Communication Speed Configuration
Dial code 5-6 to select CAN bus communication speed, speed combination
value=dial code 6
×
2 + dial code 5
×
1, the combined value range is 0-3.
The corresponding speeds are as follows:
DIP 5-6
combination value
CANIO_ADDRESS high 8-bit value CAN communication speed
0
0 (corresponds to decimal 128)
500KBPS (default value)
1
1 (corresponds to decimal 256)
250KBPS
2
2 (corresponding to decimal 512)
125KBPS
3
3 (corresponding to decimal 768)
1MBPS
⚫
Please select CAN communication speed ratio according to actual application. There
are some elements should be considered, such as, transfer distance, delay time, etc.
It is recommended to use 500K for Baud rate.