ZMC420SCAN Motion Controller Hardware Manual V1.5
→
Wiring Reference:
→
Wiring Notes:
⚫
The wiring of RS232 is as above, it needs to cross-wiring for sending and receiving
signals, and it is recommended to use a double-female head cross line when
connecting to a computer.
⚫
Please be sure to connect the public ends of each communication node to prevent
the communication chip from burning out.
⚫
Please use STP, especially in bad environments, and make sure the shielding layer is
fully grounded.
→
Cable Requirements:
Shielded Twisted Pair, and the shielded cable is grounded.
3.3.2.
Basic Usage
(1)
Please follow the above wiring instructions to wiring correctly.
Summary of Contents for ZMC420SCAN