XPCI1C00 Motion Control Card User Manual V1.0
⚫
PUL and DIR of each axis must be dialed consistently, and DIP switch of each axis
are independent.
3.8.2.
S200 DIP Switch
→
DIP Switch Appearance
→
Usage Description
4 DIP Switch (1-4) of S200 is the selection switch of initialization electric level when
power on of OUT0-
OUT31, “1” corresponds to initial high level, “0” corresponds to initial
low level.
Set Bit 1 of S200 as ON: OUT0-OUT9 reverse, OUT initial state is 0, IN initial state is
1, the DIP value is 16.
Set Bit 2 of S200 as ON: OUT10-OUT19 reverse, OUT initial state is 0, IN initial state
is 1, the DIP value is 32.
Set Bit 3 of S200 as ON: OUT20-OUT31 reverse, OUT initial state is 0, IN initial state
is 1, the DIP value is 64.
Set Bit 1 of S200 as ON: OUT initial state is 0, IN initial state is 1, the DIP value is 1.