XPCI1C00 Motion Control Card User Manual V1.0
→
Wiring Note
⚫
The wiring principle of low-speed digital input IN (0-27) is shown in the figure above.
The external signal source can be an optocoupler, a relay or a solenoid valve etc., all
can be connected as long as the requirements on output of electric level can be
achieved.
⚫
For the public end, please connect the "EGND" port on the power supply to the
negative pole of DC power supply of external input device. If the signal area power
supply of the external device and the power supply of the controller are in the same
power supply system, this connection also can be omitted.
3.7.2.
Basic Usage Method
1.
Please follow the above wiring instructions to wiring correctly.
2.
After powered on, please use ETHERNET or RS232 to connect to ZDevelop.
3.
Open or close output port directly through “OP” command, also, it can be opened or
closed thr