ECI3808 Network Motion Control Card User Manual V1.5
→
Cable Requirements:
Shielded Twisted Pair, and the shielded cable is grounded.
3.2.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use ETHERNET or RS232 (default parameter, which can be
connected directly) to connect to ZDevelop.
(3)
Please use the "CANIO_ADDRESS" command to set the master's "address" and
"speed" according to the needs, and use the "CANIO_ENABLE" command to enable or
disable the internal CAN master function, or through "ZDevelop/Controller/State the
Controller
/Communication Info” to view the CAN status intuitively, and refer to the
“ZBasic Programming Manual” for details.
(4)
Correctly set the "address" and "speed" of the slave station expansion module
according to the manual of the slave station.
Summary of Contents for ECI3808